Operating Manual GMH 3330 

Page 3 of 16

 

 

General Note 

Read this document carefully and get used to the operation of the device before you use it. Keep this 
document within easy reach near the device for consulting in case of doubt. 
 
The manufacturer is not liable for misprints.  

2  Safety  

2.1  Intended Use 

The safety requirements (see below) have to be observed. 
The device must be used only according to its intended purpose and under suitable conditions. 
Treat device and sensor carefully. Use only in accordance with above specification. (do not throw, hit 
against etc.). Protect plug and socket from soiling.  

The device combined with the combined measuring probe TFS 0100 is designed for room climate meas-
urements. This includes gauging of atmospheric humidity, temperature, dew point, dew point distance and 
enthalpy. 

Together with the flow rate measuring probes STS 005 and STS 020 the device provides flow rate meas-
urements either in water or in air. 

 

2.2  Safety signs and symbols 

Warnings are labelled in this document with the followings signs: 
 

 

DANGER 

        

Caution! 

This symbol warns of imminent danger, death, serious injuries 

and significant damage to property at non-observance.

 

 

Attention! 

This symbol warns of possible dangers or dangerous situa-

tions which can provoke damage to the device or environment at non-
observance.

 

 

Note!

 

This symbol point out processes which can indirectly influence 

operation or provoke unforeseen reactions at non-observance.

 

 
 

 

Содержание GMH 3330

Страница 1: ...93128 Regenstauf 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Digital Precision Hand held Measuring Device For Atmospheric Humidity Temperature Dew Point Dew Point Distance Enthalpy and Flow...

Страница 2: ...COMBINATION MEASURING SENSOR TFS0100 9 7 MEASUREMENTS USING FLOW MEASURING PROBES STS005 STS020 10 8 NOTES TO SPECIAL FUNCTIONS 11 8 1 ZERO DISPLACEMENT OFFSET 11 8 2 DISPLAY CORRECTION FACTOR CORR 1...

Страница 3: ...ombined with the combined measuring probe TFS 0100 is designed for room climate meas urements This includes gauging of atmospheric humidity temperature dew point dew point distance and enthalpy Togeth...

Страница 4: ...n lead to malfunctions or destroying of the device and the connected devices This device must not be run with a defective or damaged power supply unit Danger to life due to electrical shock 4 Do not u...

Страница 5: ...g 4 1 Display Depending on the measuring probes sensors connected the following measuring results can be displayed TFS 0100 Main display r H relative atmospheric humidity in Secondary display possible...

Страница 6: ...ing press Menu for 2 sec configuration menu is activated Store Quit Measurement Hold current measuring value HLD in display for flow meas in AVGHold mode start new measurement or handling of logger fu...

Страница 7: ...tc The device with pop up clip at position 90 can be set up on a table etc The device with pop up clip at position 180 can be suspended from a screw or the magnetic holder GMH 1300 Device attached to...

Страница 8: ...ll be multiplied by this factor off Factor is deactivated 1 000 Power off Selection of Power Off Delay 1 120 Power off delay in minutes Device will be automatically switched off as soon as this time h...

Страница 9: ...ergy con tent of air with a relative humidity of 0 and 0 C is 0kJ kg The warmer the air the higher the relative hu midity the higher the energy content Therefore more energy is required to heat up hum...

Страница 10: ...tions tend to be quite high To be able to display a stable measur ing value two averaging functions have been integrated in the instrument Continuous Averaging The average value displayed has been cal...

Страница 11: ...sses of all devices must not be identical In case several devices will be connected via one interface make sure to configurate the base addresses accordingly Channel 1 will be addressed by the base ad...

Страница 12: ...values a stable value has been de tected and can be taken over by means of the Store key key 6 Then the next calibration step will be displayed 3 Calibration point 2 Put sensor into suitable calibrat...

Страница 13: ...cable defective replace Values below measuring range check are there any values below the measuring range specified meas value too low Sensor cable defective replace System fault switch on again if fa...

Страница 14: ...Windows 7 Windows 8 8 1 Windows 10 Programming examples Visual Basic 4 0 Delphi 1 0 The following interface functions will be supported Channel Dll Code Name function 1 2 3 4 5 6 x x x x x x 0 Read n...

Страница 15: ...lip for table top or sus pended use Weight approx 160 g Interface serial interface 3 5mm jack serial interface can be connected to RS232 or USB inter face of a PC via electrically isolated interface a...

Страница 16: ...dequate transport package for reshipment especially for fully functional devices Please make sure that the device is protected in the package by enough packing materials 13 2 Disposal instructions Bat...

Отзывы: