GREISINGER GGO Series Скачать руководство пользователя страница 3

Z11.0.0X.6C-21 

Operating manual 

GGO -, GGA -, GOO -, GOG -

 

  page 3 of 8 

1.3. Skilled personnel 

Users of the readily installed device have to be sufficiently skilled in the operation of the device and 
able to avoid risks. The operator of the arrangement is responsible for sufficient qualification the 
operators.

 

1.4. Safety signs and symbols 

Warnings are labelled in this document with the followings signs: 

 

Caution!

  

This symbol warns of imminent danger, death, serious injuries and significant 
damage to property at non-observance. 

 

Attention!

  

This symbol warns of possible dangers or dangerous situations which can pro-
voke damage to the device or environment at non-observance. 

 

Note!

  

This symbol point out processes which can indirectly influence operation, pos-
sibly cause incorrect measurement or provoke unforeseen reactions at non-
observance. 

 

Caution, acid! 

 

This symbol warns of danger to living tissue and many materials, that can be 
damaged or destroy by exposure to that chemical. 

 

1.5. Reasonably foreseeable misuse 

1.   

  

 

This device must not be used at potentially explosive areas!  
Do not use these products as safety or emergency stop devices or in any other 
application where failure of the product could result in personal injury or material 
damage. 
Failure to comply with these instructions could result in death or serious injury 
and material damage. 

2.   

 

This device must not be used at a patient for diagnostic or other medical 
 purpose. 

 

 

Содержание GGO Series

Страница 1: ...NY 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Operating Manual Oxygen partial pressure sensor in specialized housing GGO GGA GOO GOG ResOx Please read these instructions carefully before us...

Страница 2: ...ly read and understood this manual before starting any work The manufacturer will assume no liability or warranty in case of usage for other purpose than the intended one ignoring advices of this manu...

Страница 3: ...age to the device or environment at non observance Note This symbol point out processes which can indirectly influence operation pos sibly cause incorrect measurement or provoke unforeseen reactions a...

Страница 4: ...has adjusted to the ambient temperature before trying a new start up 7 The sensor contains KOH GOEL 381 or acid GOEL 370 KOH and acid can cause severe chemical burns If leaking avoid contact If there...

Страница 5: ...are available which happens normally at the end of life time The nominal life time can be shortened significantly by usage Influencing factors are Storage Operation temperature Humidity of measured ga...

Страница 6: ...th pressure connection If You use an instrument with pressure connection e g GMH 3695 this type is optimal Especially at systems with over or under pressure or at dy namic pressure due to gas flow It...

Страница 7: ...crew in sensor 3 in part 1 Do not forget O Ring 2 Unscrew the sensor carefully e g by means of suitable nippers The audio plug of part 4 has to be connected to the socket in the sensor If this makes p...

Страница 8: ...rolyte basic acidic Connection approx 1 m cable Temperature sensor integrated Storage temperature 15 to 60 C Operating ambient 0 45 C 0 50 C Ambient pressure 0 6 1 75 bar abs 0 5 to 2 0 bar abs Over u...

Отзывы: