E39.0.0X.6C-03                                               Operating instruction T-Logg 100 and T-Logg 100 E                                                                page 4 of 6

BATTERY

:

• Changing display

 

BAT

 / Value:

  The battery of the 

T-Logg

 is getting discharged soon.

  Replace the battery briefly. Even so data logging is still active.

• Constant display 

BAT

:

  The Logger battery is empty now and data logging has been stopped.
  Replace the battery immediately.

ALARM LOW

:

The temperature measured is below the min. alarm limit.

ALARM HIGH

:

The temperature measured has exceeded the max. alarm limit.

ERROR 1

:

The temperature has exceeded the measuring range of the logger.

ERROR 2

:

The temperature has been fallen below the measuring range of the logger.

ERROR 7

:

The 

T-Logg

 has detected a system fault.

 Remedy:

  Remove battery and wait about 30 minutes. Then insert the battery again.

 If the error message displayed furthermore, please send the logger to the

  manufacturer to repair.

7  Battery service life and recording time

Measuring cycle:

2 sec.

10 sec.

15 min.

5 hours

Recording time:

8.9 hours

44 hours

166 days

Approx. 9 years

Battery service life:

   —   

Approx. 1 year

Approx. 3 years

   —   

Please note!

Short measuring cycles as well as frequently measuring data transfer result in a reduction of
the battery service life!

Even if the T-Logg is connected, power consumption is increased. So it’s important to
connect the logger with the USB interface of the PC only as long as necessary!

Содержание T-Logg 100

Страница 1: ...REISINGER electronic GmbH D 93128 Regenstauf Hans Sachs Straße 26 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Data logger for temperature as of version V1 3 Operating Manual T Logg 100 T Logg 100 T Logg 100 E ...

Страница 2: ...he device 1 Trouble free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under Specification To protect the battery the max permissible storage and transport temperature of the device is 85 C 2 General instructions and safety regulations for electric light and heavy current plants including domestic sa...

Страница 3: ...ay is to indicate the temperature Depending on the operating mode of the logger other messages will be displayed as well STOP The T Logg is stopped No data are recorded The logger memory is empty The logger is reset and can be restarted HALT The T Logg has been halted The stored data can be read The logger memory is not empty DISPLAY OF TEMPERATURE The small arrow is flashing The logger is active ...

Страница 4: ...erature has been fallen below the measuring range of the logger ERROR 7 The T Logg has detected a system fault Remedy Remove battery and wait about 30 minutes Then insert the battery again If the error message displayed furthermore please send the logger to the manufacturer to repair 7 Battery service life and recording time Measuring cycle 2 sec 10 sec 15 min 5 hours Recording time 8 9 hours 44 h...

Страница 5: ...he PCB and deposit it carefully beside the housing with the LCD display face down Take care not to damage the gasket 3 Push out the button cell carefully from socket see picture at the top on the right 4 Insert the new button cell type CR 2032 with correct polarity in the socket the positive pole is on the retaining bracket see picture at the bottom on the right 5 Reinsert the PCB correctly LCD fa...

Страница 6: ... are monitored at alarm limits Alarm limit and alarm delay 0 500 min adjustable via interface Nominal temperature 25 C Working temperature 25 60 C Storage temperature 30 85 C Battery CR 2032 exchangeable Battery service life approx 3 years if interval is 15 min depending on measuring cycle and operating temperature Interface Serial interface 3 pin miniature plug Data communication via interface co...

Отзывы: