E39.0.0X.6C-03                                               Operating instruction T-Logg 100 and T-Logg 100 E                                                                page 6 of 6

Specification

T-Logg 100

T-Logg 100 E

Measuring range:

-25.0 … +60.0 °C

-25.0 ... +120.0 °C

Resolution:

0.1°C (display and memory)

0.1°C (display and memory)

Accuracy:

 

(at nominal temperature)

< ± 0.5 °C

< ± 0.2 % of meas. value ± 0.5 °C

Sensor:

Integrated in device

sensor tube made of stainless steel, Ø 5 mm,
approx. 50 mm long, approx. 1 m silicone
cable with anti-bucking glanding to housing.

Display:

LCD display, 10 mm high, 4-digit

Recording interval:

2s to 5h

Measuring value memory:

16,000 values

Memory type:

FILLING MEMORY

:

>> Once the memory is filled with data, the recording will automatically be halted.

RING MEMORY

:

>> The old data will be overwritten in case of memory overflow.

Recording time:

approx. 9 hours up to 9 years, depending on measuring cycle.

Alarm function:

the measured values are monitored at alarm limits.
Alarm limit and alarm delay (0 ... 500 min.) adjustable via interface.

Nominal temperature:

+25 °C

Working temperature:

-25 … +60 °C

Storage temperature:

-30 … +85 °C

Battery:

CR 2032, exchangeable.

Battery service life:

approx. 3 years (if interval is 15 min.), depending on measuring cycle and operating
temperature.

Interface:

Serial interface, 3-pin miniature plug.

Data communication:

via interface converter.

Dimensions / housing:

48.5 x 48.5 x 35.5 mm (H x W x D), plug an fixation flap not included.
Housing made of shock resistant plastic, transparent front made of
polycarbonate, splash water-proof: IP 65.

EMC:

The 

T-Logg 100

 have been manufactured in accordance with the regulations

concerning EMC (2004/108/EG).
The device meets EN61326 (appendix A, class B).
Additional error: < 0.5% (T-Logg 100) or < 1% (T-Logg 100 E).

10 Disposal instructions:

The device must not be disposed in the regular domestic waste. Send the device directly to us (sufficiently
stamped), if it should be disposed. We will dispose the device appropriate and environmentally sound.

Содержание T-Logg 100

Страница 1: ...REISINGER electronic GmbH D 93128 Regenstauf Hans Sachs Straße 26 49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Data logger for temperature as of version V1 3 Operating Manual T Logg 100 T Logg 100 T Logg 100 E ...

Страница 2: ...he device 1 Trouble free operation and reliability of the device can only be guaranteed if the device is not subjected to any other climatic conditions than those stated under Specification To protect the battery the max permissible storage and transport temperature of the device is 85 C 2 General instructions and safety regulations for electric light and heavy current plants including domestic sa...

Страница 3: ...ay is to indicate the temperature Depending on the operating mode of the logger other messages will be displayed as well STOP The T Logg is stopped No data are recorded The logger memory is empty The logger is reset and can be restarted HALT The T Logg has been halted The stored data can be read The logger memory is not empty DISPLAY OF TEMPERATURE The small arrow is flashing The logger is active ...

Страница 4: ...erature has been fallen below the measuring range of the logger ERROR 7 The T Logg has detected a system fault Remedy Remove battery and wait about 30 minutes Then insert the battery again If the error message displayed furthermore please send the logger to the manufacturer to repair 7 Battery service life and recording time Measuring cycle 2 sec 10 sec 15 min 5 hours Recording time 8 9 hours 44 h...

Страница 5: ...he PCB and deposit it carefully beside the housing with the LCD display face down Take care not to damage the gasket 3 Push out the button cell carefully from socket see picture at the top on the right 4 Insert the new button cell type CR 2032 with correct polarity in the socket the positive pole is on the retaining bracket see picture at the bottom on the right 5 Reinsert the PCB correctly LCD fa...

Страница 6: ... are monitored at alarm limits Alarm limit and alarm delay 0 500 min adjustable via interface Nominal temperature 25 C Working temperature 25 60 C Storage temperature 30 85 C Battery CR 2032 exchangeable Battery service life approx 3 years if interval is 15 min depending on measuring cycle and operating temperature Interface Serial interface 3 pin miniature plug Data communication via interface co...

Отзывы: