background image

2

Page

Content

3

View of the Compact 900

4

The Compact  900 presents itself

5

Start up

6

Menu selection

7

Adjustment contrast

8

Adjustment date/time

9

Adjustment language

10

Adjustment printer 

11

Testing mechanical watches

12 + 13

Display mechanical watch

14

Testing watches with no standard beat rate

15 + 16

Testing quartz watches with  „QM06“

17+18

Testing quartz watches with  „EM06“

19

Checking battery voltage

20

Measuring stepper motor ohms

21+22

Testing pendulum clocks with  „OPTO6“ ( optical )

23+24

Testing pendulum clocks with  

„CM06“    ( acoustical )

25

Finding unknown beat rate for pendulum clocks

26

Programming of a button  ( P1 to P9 )

27

Changing automatic adjustment

28

Changing a program name

29

Editing printoud header

30+31

Adapter, microphones for Compact 900

32

Standard - beat rates / CE 

– Conformity

33 +34

Co-Axial watch

Содержание Compact 900

Страница 1: ...rmany Tel 49 7231 9535 0 Fax 49 7231 9535 95 info klein messtechnik de www klein messtechnik de Greiner Compact 900 Version 11 2011 Greiner Vibrograf AG Mittelstrasse 2 4900 Langenthal Switzerland T 4...

Страница 2: ...Testing quartz watches with QM06 17 18 Testing quartz watches with EM06 19 Checking battery voltage 20 Measuring stepper motor ohms 21 22 Testing pendulum clocks with OPTO6 optical 23 24 Testing pend...

Страница 3: ...or for watch signal Serial interface for printer and PC Plug for 12 Volt adaptor Plugs for electric measurements Plugs for electric measurements Plug for MP86M Plug for CM06 Plug for QM06 OPTO06 and A...

Страница 4: ...able from 0 5 to 3 3 Volt Checking of Battery as well as stepper motor ohms Pendulum clocks Graphical and alphanumeric indication of Measuring of rate error with light barrier OPTO 06 or with acoustic...

Страница 5: ...itched on If your data as your name address tel etc have been programmed they will appear instead of the Greiner logo printout header Standby If the Compact 900 is on and during 10 minutes is no watch...

Страница 6: ...hange various settings Menu P 1 18000 52 P 2 19800 52 P 3 21600 52 P 4 28800 52 P 5 36000 52 Co Axial Press this key for automatic operation Auto mode More 10 06 2009 18 37 Menu P9 Pende l auto P7 Qua...

Страница 7: ...ment contrast Button for more system adjustments 10 06 2009 18 37 Settings System Modify auto mode settings Modify program Dis play con trast Info Back 08 27 26 01 02 03 Dis play con trast 10 06 2009...

Страница 8: ...ore Back 29 09 Date time Value Back 28 08 2007 15 12 Set clock Select 04 Press button up or down for adjusting the sound of the click 05 Press button for the service center 07 Press button to select t...

Страница 9: ...olski Fran ais Italiano Espa ol Portugu s Svenska Menu after start Select language by pressing buttons in following sequence Select language with the following buttons For saving the language Menu P 1...

Страница 10: ...18000 52 P 2 19800 52 P 3 21600 52 P 4 28800 52 P 5 36000 52 Co Axial More Menu after start Select printer by pressing buttons in following sequence Select printer with these buttons For saving the se...

Страница 11: ...clamp microphone CM06 2 Press button Auto Mode for starting the automatic measurement or choose button P1 to P6 for selecting a specific program if the beat rate is known MP86 QM06 CM06 Menu Co Axial...

Страница 12: ...al View rate error More One two beat diagram View rate diagram Press button to change between one or two beat diagrams Press button for the previous display Display of mechanical watch Indication of t...

Страница 13: ...s d 260 0 2ms 30 25 20 15 10 5 0 5 10 15 20 25 30 130 180 240 300 350 More Rate Amplitude Out of beat Auto mode mechanical watch Target rate 21600 b h Lift angle 52 Measuring period 4 s Speaker on of...

Страница 14: ...21476 A h Testing watches with no standard beat rate If a watch has no standard beat rate p 32 or the rate error is higher then 300s d the following display appears Indication of measured beat rate P...

Страница 15: ...asurement of the quartz frequency or motor impulses press first button More then button P7 or P8 QM06 The pins fork receive acoustically the 32 kHz frequency of the quartz if the vibrations are suffic...

Страница 16: ...e 5 4 3 2 1 0 1 2 3 4 5 Rate 3 s month Impulse Remaining Inhibition 1 00 s 3 s 60 s Press button for the next menu Testing quartz watches with QM06 Press button to return to menu above Indication for...

Страница 17: ...It is also possible to use only the test cable without EM06 For the following menu press button EM06 in the main menu Choose then button for measuring consumption of electricity rate accuracy stepper...

Страница 18: ...e diagram Press this button for the following menu Voltage lower Voltage higher 0 10 s d 1 s 0 27 A Remaining Rate 3 s 3 s month Voltage lower Voltage higher Press button to return to display above Au...

Страница 19: ...u Battery voltage Menu start diagram Source voltage 1 55 V 22 08 2007 10 39 1 450 V Back Connect test cable with the plugs of the Compact 900 Touch with red probe the positive side and with the black...

Страница 20: ...with the plugs of the Compact 900 Then connect the ends of the probes to a short circuit and press button Zero Ohms Display indicates 0 Ohm Then touch with the probes the ends of the stepper motor The...

Страница 21: ...50mm The pendulum shall pass through the light beam only one sided The correct adjustment can be checked by the red signal of the Compact 900 Press this button to begin the automatic start of the meas...

Страница 22: ...10 15 20 25 30 Rate 8 s d View rate diagram Press button to return to display above View rate error More Rate 8 s d Testing pendulum clocks with OPTO6 optical Auto mode pendulum clock Target rate 896...

Страница 23: ...ufficiently receivable The red signal on the Compact 900 indicates the noise of the frequency of the pendulum clock P9 Pendel auto Press this button to start After approx 8 sec appears the next displa...

Страница 24: ...ng pendulum clock with CM 06 acustically Graphic indication of rate error with the microphone Opto06 Press button for next display View rate diagram Press button to return to display above P9 Pendel a...

Страница 25: ...for example 2 hours 3 After a time xx press button stop measure 4 Press button value in order to give in the passed time of the pendulum for example 2 hours 2 minutes 0 seconds 5 Press button set targ...

Страница 26: ...the value 3 Press Modify program name to change the name of this program 4 Press Standard values for factory setting View program settings Modify program settings Pro gram Back Pro gram Watch type Me...

Страница 27: ...ues Select Select To indicate the parameters press the following buttons in the main menu button Settings then button Modify auto settings Changing automatic adjustments Auto mode Auto MP06 only Auto...

Страница 28: ...ghijklmnopqrstuvwxyz0123456789 ABCDEFGHIJKLMNOPQRSTUVWXYZ New line Caliber 3150 P 1 Caliber 3150 P 1 P 1 Caliber 3150 Use the Cursor to move to the desired position Right or left Use Character To move...

Страница 29: ...rintout header The printout header appears after switch on the Compact 900 and he is printed together with the results The printing of the results has following appearance To program or modify the pri...

Страница 30: ...l and quartz watches Microphone MP86 Suitable for testing Mechanical watches Head is fixable in all positions Light barrier OPTO 06 For testing of pendulum clocks optical measuring of the pendulousnes...

Страница 31: ...the rate error of quarz watches Test cable For manual measuring of consumption of electricity and rate error of quarz watches as well as testing of the Stepper Motor ohms and the battery voltage Micro...

Страница 32: ...0 12240 12600 12960 13320 13680 14040 14400 14760 15120 15480 15840 16200 16560 16920 17280 17640 18000 18360 18720 19080 19440 19800 20160 20520 20880 21240 21600 21960 22320 22680 23040 23400 23760...

Страница 33: ...or Co Axial 25200 38 or Menu to return Info Select key Co Axial for Co Axial escapement see menu on page 11 P 5 36000 52 More For automatic operation press this key Auto Mode Co Axial watch For the co...

Страница 34: ...eriod 4 s Rate Amplitude Out of beat 8 s d 213 0 6ms 130 180 240 300 350 Speaker on off View balance wheel signal View rate error More Display if Co Axial watch is in test Co Axial Auto The Compact 90...

Отзывы: