16
View
rate
error
More…
Auto mode, quartz watch
Measuring period: Auto s (60)
Vertical Zoom: 1 x
Rate:
+ 0.08 s/d
BIS HIER O.K.
Rate:
+0.10 s/d
More…
- 5 - 4 -3 2 -1 0 1 2 3 4 5
Rate:
3 s/month
Impulse: Remaining: Inhibition:
1.00 s 3 s 60 s
Press button for
the next menu
Testing quartz watches with „QM06“
Press button to return to menu above
Indication for watches with
pulse sequence higher then
1 sec. for example (5,10,20,60)
Auto mode, quartz watch
Measuring period: Auto s (60)
View
rate
diagram