4
s
TarTIng
Y
our
I
nsTallaTIon
Check the following list of components to ensure that all parts are packed with your system.
1 - Storage Tank
1 - RO System
1 - Faucet
1 - Installation Kit
Determine the location for the installation of the RO system. Avoid locations where the system might come in contact with
hot water pipes or other hazards. Determine the location for the faucet. Check to see that drilling the faucet hole will not
damage pipes or wires running underneath the sink. Determine the location for the storage tank. A maximum distance from
tank to faucet of 15 feet is possible. The system will produce a faster flow at the faucet with the shortest tubing run from
tank to faucet.
Preparation
Fittings and Tubing
All tubing is individually labeled and colour coded for ease of installation.
1/4” Black - Connects the feed water valve to the RO pre-filter
3/8” White - Connects the RO membrane product port to the storage tank
1/4” Orange - Connects the membrane brine port to the drain connector
3/8” Blue - Connects the postfilter to the faucet
John Guest™ fittings are used throughout the system.
To insure a optimal seal, tubing should be cut with the end
square. An angled cut or distortion of the tubing will not
provide an efficient seal and may cause leaks.
To Install a tube, push in the collet until it seats firmly.
To remove a tube, push in the collet and pull out the tube
.