  5. OPERATING YOUR WALL CONTROLS 

(CONTINUED)

RD-4P MODEL

TM

DEHUMIDISTAT PROFESSIONAL

FEATURES

• Dehumidistat to select the humidity level
• Range Control (OFF, NORMAL and REDUCED)
• Mode Control (INTERM and CONT)
• Cycles per hour (0/0, 20/40 and 30/30)
• Green LED light on = OVERRIDE
• Orange LED light on = CONT/INTERM
• LED light maintenance reminder

Comes complete with Relative Humidity Sensor Dial, Speed Control 

Selector Switch, Mode Selector Switch, Cycles per Hour Selector 

Switch and Maintenance Reminder Feature.

RELATIVE HUMIDITY SENSOR DIAL (OFF/60%/COMFORT ZONE/30%):

• Overrides the ventilation system to high speed once the level of 

humidity is above the set point.

• If the wall control is in CONT or INTERM mode the ventilation 

system will automatically return to its original mode once the level of 

humidity is below the set point.

 

NOTE:

 By turning the relative humidity Sensor Dial to the OFF position does 

not turn off the ventilation system. It only deactivates the relative humidity 

sensor.

RANGE SELECTOR SWITCH (OFF/NORMAL/REDUCED):

• 

OFF

 – Sends command to turn off the ventilation system.

• 

NORMAL

 – The ventilation system operates on installers set speeds 

(CONT and OVERRIDE)

• 

REDUCE

 – The ventilation system operates at 30% reduction in CONT 

and 15% in OVERRIDE set speed

 

NOTE:

 REDUCE mode will not decrease below the minimum low speed 

of the ventilation system.

MODE SELECTOR SWITCH (INTERM/CONT):

• 

INTERM

 – When the selector switch is in the INTER position the 

ventilation system will only run on high speed when there is a request 

for ventilation. At this time the unit will run on high speed until the 

level of humidity is below the set point, The T-3 timer has completed 

its time period or once the cycles per hour has completed its cycle.

• 

CONT

 – Provides continuous ventilation. The ventilation system will 

increase to high when there is a request from one of the wall controls. 

(Recommended for maximum indoor air quality.)

CYCLES / HOUR SELECTOR SWITCH (0; 20/40; 30/30):

• 

0

 – The ventilation system operates at the settings of your RD Series 

wall control.

• 

20/40

 – The ventilation system cycles automatically for 20 minutes 

at high speed and returns to previous settings (CONT or INTERM) 

pending settings on the mode selector switch on your RD series wall 

control.

• 

30/30

 – The ventilation system cycles automatically for 30 minutes 

at high speed and returns to previous settings (CONT or INTERM) 

pending settings on the mode selector switch on your RD series wall 

control.

 NOTE:

 The ventilation system will go to high speed if a demand from 

any remote wall control is activated when in the 2nd stage of cycle. 

(Ex: 40 or 30 minutes)

MAINTENANCE REMINDER LIGHT:

• LED is lit after 90 days consecutive power to the ventilation system.
• To reset the maintenance LED reminder, put the range selector switch 

to the OFF position.

Installation of a RD-Series main wall control with your HRV/ERV will improve 

comfort and may significantly reduce the product’s energy use.

Содержание C3.14 HRV

Страница 1: ...MODEL PE 7 15 PE 10 22 SS 3 80 Product of Greentek Greentek reserves the rights to modify a product without prior notice whether in price design color or codes in order to offer at all times quality products that are highly competitive Greentek 50 Kanalflakt Way Bouctouche NB E4S 3M5 1 888 724 5211 Fax 1 866 426 7430 www Greentek ca Item 463674 SEPT2018 ...

Страница 2: ...ons 3 3 Description of your Ventilation System 4 4 Operation of the DuotrolTM System 5 5 Operation of your Wall Controls 6 11 6 Troubleshooting 12 7 Maintenance 12 8 Warranty 13 Before servicing or cleaning the HRV system always remove the power cord from the AC wall outlet To reduce the hazards of electric shock or fire do not perform any service to the HRV system other than those stated in the o...

Страница 3: ...m the heat from the outgoing stale air and use this heat to temper the incoming fresh air which reduces the cost of effectively ventilating your home during winter NOTE Reverse process occurs in the summer months Fresh air Exhaust air Bathroom Control Forced air system HRV ERV Exhaust air hood Fresh air supply hood Exhaust and supply in the return Bathroom Control Forced air system HRV ERV Exhaust...

Страница 4: ...nected to the drain pan and serves as drainage for the accumulation of water It is normal during summer months to find no condensation in drain pan or in drainage hose Automatic Defrost Sequence The defrost sequence is electronically controlled to measure the incoming outdoor air temperature the sequence is activated at 5 C 23 F and colder This system eliminates that the heat recovery or energy re...

Страница 5: ...h speed until the level of humidity is below the set point The T 3 timer has completed its time period or once the cycles per hour has completed its cycle TIP During hot and humid days it is recommended that you put the system on INTERM mode This will reduce the amount of warm and humid fresh air coming inside the house NOTE The following controls EHC1 0 EHC1 5 RD 2 RD 3P RD 3D RD 4P RD 4D will ov...

Страница 6: ...tion system will increase to high speed when a auxiliary control has been activated if installed Recommended for best indoor air quality ECO Friendly continuous ventilation energy savings mode The ventilation system operates at reduced rate of 30 in continuous and at a reduced rate of 15 during maximum ventilation speed RECIRC Recirculation ventilation mode The recirculation mode recycles already ...

Страница 7: ...l of humidity is below the set point NOTE By turning the relative humidity Sensor Dial to the OFF position does not turn off the ventilation system It only deactivates the relative humidity sensor RD 2 MODELTM DEHUMIDISTAT FEATURES Dehumidistat to select the humidity level Range Control OFF NORMAL and REDUCED Green LED light on OVERRIDE Orange LED light on CONT INTERM Comes complete with Relative ...

Страница 8: ...eated ambient air from a selected area and distributes throughout your home This enables the ventilation system to have an auxiliary air supply automatically during defrost sequence or when RECIRC mode is selected RD 3P MODELTM DEHUMIDISTAT PROFESSIONAL FEATURES Dehumidistat to select the humidity level Range Control OFF NORMAL and REDUCED Mode Control INTERM and CONT Green LED light on OVERRIDE O...

Страница 9: ... SWITCH INTERM CONT INTERM When the selector switch is in the INTER position the ventilation system will only run on high speed when there is a request for ventilation At this time the unit will run on high speed until the level of humidity is below the set point The T 3 timer has completed its time period or once the cycles per hour has completed its cycle CONT Provides continuous ventilation The...

Страница 10: ...er has completed its time period or once the cycles per hour has completed its cycle CONT Provides continuous ventilation The ventilation system will increase to high when there is a request from one of the wall controls Recommended for maximum indoor air quality RECIRC The recirculation mode recycles already heated ambient air from a selected area and distributes throughout your home This enables...

Страница 11: ...ess button once this will deactivate T 3 push button time and your ventilation system will return to previous settings TIPS The T 3 model push button timer allows the homeowner control of the indoor humidity level in room were excess humidity is produced Ex Bathroom kitchen laundry room TIPS Always leave a small gap when closing curtains and blinds in the winter months this will allow proper circu...

Страница 12: ...aged 7 Arrange for an annual servicing Your HRV ERV should undergo annual general servicing by a certified contractor and who is familiar with your HRV If possible have your furnace and HRV serviced at the same time this will result in less inconvenience and cost than two separate visits QUESTION ITEM DIAGNOSIS SOLUTION HRV ERV not running Verify breaker in main electrical panel Verify the HRV or ...

Страница 13: ... Years PH7 15 PH7 15ES XPH1 5 PE7 15 PH10 22 PH10 22ES XPX2 0 PE10 22 XDH7 15 C3 14HRV SS3 80 HRV SS3 80ERV 2 Years RNC12 RNC1 0 RNC1 5 RNC2 0 RNC2 0ES LIMITED WARRANTY ON VENTILATION MOTORS Greentek warrants the ventilation motors against defects in material and workmanship within the models warranty period from the date of original installation Greentek will provide a new or remanufactured part ...

Страница 14: ...50 Kanalflakt Way Bouctouche NB E4S 3M5 1 888 724 5211 Fax 1 866 426 7430 www greentek ca Item 463674 ...

Отзывы: