- 15 -
● Bad quality water will produce more lime scale and sand: this kind of water should be filtered and
demineralized.
●The water quality should be analyzed before operating the unit: PH value, conductivity, chloride ion
concentration and sulphate ion concentration should be checked.
●Acceptable water quality shown below:
PH value
Total hardness
Conductivity
Sulphate ion
Chlorine ion
Ammonia ion
7
~
8.5
< 50ppm
<200μV/cm(25
℃
)
None
< 50ppm
None
Sulfate ion
Silicon
Iron content
Sodium
Ca
< 50ppm
< 50ppm
< 0.3ppm
No requirement
< 50ppm
● Suggested filter mesh = 40.
6.Installation of optional accessories
6.1 Selection of the water pump
●The circulation pump is required for the system to operate, there is a terminal connection for the pump
(single phase)
NOTE
For single-phase pumps, please check the wiring diagram.
●Head of circulation pump = height difference between water level and main unit + total pipeline resistance
(determined by the hydraulic calculation) + pressure loss of main unit (see nameplate on heat pump).
NOTE
Multiple units installed in parallel place more demand on the water pump requirement.
6.2 Water pipe selection
●The selection of the water pipe should be based on the actual system specifications
●The flow switch can be installed horizontally or vertically. If installed vertically, th
e direction of the water
Содержание BYC-007TH1
Страница 20: ... 20 Figure 12 Electrical wiring diagram ...
Страница 25: ... 25 ...
Страница 27: ... 27 4 Timer Setting 4 1 Icon Definitions Multiple phase timer setting Timer ON OFF Time ...
Страница 40: ... 40 The phone needs to be connected to the network through the WIFI network Need to select Agree ...
Страница 52: ... 52 12 Fault analysis and elimination method ...