- 14 -
5.2.2 Pipeline installation diagram
Controller
Heat
Pump
Water temp sensor wire
.
Swimming Pool
Pump signal wire
Pump
Drainage
Drainage
Feeding water
Figure 7 Diagram
(
Single unit for reference
)
● It is recommended to install a one-way valve for each unit to prevent water back flow.
● Multiple units can be installed as part of a system, but each unit should be controlled independently.
● All pipes and valves should be insulated.
5.2.3 Connection sizes
N º de Modelo.
Entrada
Salida
BYC-007TH1
BYC-010TH1
BYC-013TH1
BYC-017TH1
BYC-021TH1
BYC-030TH1
DN50
DN50
●The pipe pressure and flow rate should be calculated before selecting the diameter of the pipe, pressure
drop range is 0.3
〜
0.5 kgf/cm2(3
〜
5m
)
head pipe flow rate range is 1 .2
〜
2. 5 m/s.
●The hydraulic calculation should be made after selecting the pipe diameter. If the resistance is more than
the pump head, then a more powerful pump or larger pipes are required.
5.2.4 Required Water Quality