9
GPI-100 TRAVELLING IRRIGATOR OPERATION MANUAL
GPI-100 - Sprinkler throw rates and average expected rainfall
Nozzle
mm
Pressure
PSI
Pressure
BAR
Radius
max.m
Diametre
max.m
Flow
l/m
Rainfall
calculator
(mm) 1 .5 Hours
Rainfall
calculator
(mm) 5 Hours
Rainfall
calculator
(mm) 8 Hours
5
22
29
44
58
73
1.5
2
3
4
5
13.5
14.0
15.0
16.0
17.0
27
28
30
32
34
18
22
26
30
34
0.6
0.7
0.8
0.8
0.9
2.0
2.4
2.6
2.8
3.0
3.2
3.8
4.2
4.5
4.8
6
22
29
44
58
73
1.5
2
3
4
5
14.0
14.5
15.5
17.0
18.0
28
29
31
34
36
27
31
38
44
49
0.9
1.0
1.1
1.2
1.2
2.9
3.2
3.7
3.9
4.1
4.6
5.1
5.9
6.2
6.5
7
22
29
44
58
73
1.5
2
3
4
5
14.5
15.0
16.0
17.5
18.5
29
30
32
35
37
37
42
52
60
67
1.1
1.3
1.5
1.5
1.6
3.8
4.2
4.9
5.1
5.4
6.1
6.7
7.8
8.2
8.7
8
22
29
44
58
73
1.5
2
3
4
5
15.0
15.5
17.0
18.5
19.0
30
31
34
37
38
49
55
68
78
88
1.5
1.6
1.8
1.9
2.1
4.9
5.3
6.0
6.3
6.9
7.8
8.5
9.6
10.1
11.1
GPI-100 - Pressure Loss Chart
5
Inlet Pressure
Outlet Pressure
Spray Range
20psi
9psi
10m
40psi
20psi
14m
60psi
31psi
16m
80psi
42psi
18m
100psi
53psi
20m
6
Inlet Pressure
Outlet Pressure
Spray Range
20psi
14psi
10m
40psi
30psi
13m
60psi
45psi
15m
80psi
61psi
17m
100psi
83psi
20m
7
Inlet Pressure
Outlet Pressure
Spray Range
20psi
11psi
9m
40psi
24psi
13m
60psi
37psi
16m
80psi
51psi
18m
100psi
63psi
20m
8
Inlet Pressure
Outlet Pressure
Spray Range
20psi
9psi
9m
40psi
20psi
11m
60psi
33psi
14m
80psi
43psi
15m
100psi
54psi
17m
Data reported here is only indicative and not binding.
Pressure intended at the nozzle.
4
spray data