Maintenance
Wear eye protection when operating
or servicing this tool.
Failure to wear eye protection could
result in serious eye injury from
flying debris or hydraulic oil.
Each Operating Day
Before use:
1. Inspect indenter and head for wear or damage such
as cracks, gouges, or chips.
2. Inspect the tool for damage or leaks. If damage is
detected, return the tool to an authorized Greenlee
service center for inspection.
High pressure hazard:
Do not use fingers or hands to
check for oil leaks. High pressure
oil easily punctures skin causing
serious injury, gangrene, or death.
If injured, seek medical help immedi-
ately to remove oil.
After use:
1. Wipe all tool surfaces clean with a damp cloth and
mild detergent.
Do not use solvents or flammable
cleaners to clean the tool body.
Solvents could ignite, causing
serious injury or property damage.
2. Fully retract the ram. Place tool in the carrying case.
Store in a cool, dry place.
Monthly
1. Thoroughly clean all surfaces.
2. Check the oil level.
3. Oil the pin joints, and metal surfaces that slide.
Annually or After 10,000 Cycles
1. Change the hydraulic oil.
2. Return the tool to an authorized Greenlee service
center for inspection.
Checking the Oil Level
1. Remove the two screws holding the tank housing
cover.
2. Remove the tank housing cover.
3. Point the head towards the ground and remove the
oil plug. Add oil if necessary.
4. Replace the oil plug and the tank housing cover.
Secure with screws.
Recommended Hydraulic Oils
AVIA
®
HVI 15
Shell Tellus T 15
Mobil
®
DTE 11M
NUTO
®
H 15