Greenlee CM-1360 Скачать руководство пользователя страница 7

CM-1360 • CM-1560 • CMH-1000 • CMI-1000

7

Using the Features

All Models

• 

Intelligent Auto Power Off (APO):

  The meter automatically turns off after approximately 32 minutes 

of inactivity to extend battery life. Active meter function is specified as: selector switch is rotated or 
pushbuttons are pressed; readings above 8.5% of the range; non-OL readings for resistance, continuity, 
or diode function; non-zero readings for Hz function; phase rotation segment moving. To wake up the 
meter from APO, press the 

SELECT

 button momentarily and release or turn the rotary switch 

OFF

 and 

then back on. Always turn the rotary switch to the 

OFF

 position when the meter is not in use.

•  

:

 Press the 

 button momentarily to toggle the LCD backlight. The backlight automatically 

turns off after 32 seconds to extend battery life.

• 

:

 Press the 

 button momentarily to toggle the flashlight. The flashlight automatically turns off 

after 32 seconds to extend battery life.

• 

 CREST:

  Press for 1 second to activate. LCD will indicate   when mode is active. This mode will 

capture current or voltage peaks in duration of as small as 5 ms. Press 

CREST

 to toggle between MIN 

and MAX. Add 250 digits to accuracy for changes > 5 ms.

• 

 HOLD:

  Press momentarily to hold the present value on the display. Press again to exit this mode.

• 

 REC:

  Press momentarily to activate MAX/MIN/AVG recording mode. 

 

and “MAX MIN AVG” appear 

on the display. The meter beeps when new maximum or minimum reading is updated. The average 
reading is calculated over time. Press the button momentarily to read the MAX, MIN, and AVG readings 
in sequence. Press the button for 1 second to exit MAX/MIN/AVG recording mode. APO is disabled 
automatically in this mode.

• 

SELECT:

  Press momentarily to toggle between functions, measurement modes, or display modes. The 

last used setting becomes the default when that function is selected again. To change the default, select 
a new setting. The setting will be stored in nonvolatile memory.

• 

Δ:

 Press the 

Δ 

button for 1 second to toggle between zero and normal mode. In zero mode the value 

on the LCD when the button is pressed becomes the offset. As the input value changes, the offset is 
subtracted from the actual value. This modified value is shown on the LCD.

Note: 

Δ 

operation when DCA or DC + ACA functions are selected offsets any magnetic hysteresis in the 

jaw. If DCA or DC + ACA reading before measuring is not zero, press the 

Δ 

button for 1 second. The LCD 

will display “dc_0”. When this clears, the meter is ready for operation. When measuring more than 5 A, 
this mode is disabled. As an indication, the meter will beep three times.

CM-1560, CMH-1000, and CMI-1000 Only

• 

PEAK-RMS:

 Press the 

PEAK-RMS

 button for 1 second to activate PEAK-RMS mode to capture inrush 

current or voltage in duration as short as 80 ms. 

 appears on the display. Press the button for 

1 second to exit PEAK-RMS mode. APO is disabled automatically in this mode.

CMH-1000 and CMI-1000 Only

•  

 and 

:  If desired, press and hold the 

REC

 button while turning the meter ON to enable the Beeper 

feature. If the segments indicate a clockwise movement, the beeper sounds a single long beep per 
segment cycle. If the segments indicate a counterclockwise movement, the beeper sounds three short 
beeps per segment cycle.

•  

:  Ensure the motor is electrically isolated from its power source. Press the 

SELECT

 button 

momentarily to select Motor function. Connect the meter to the motor as described in the “Settings 
Table” section of this manual. From the perspective of looking down the shaft of the motor, spin it 
clockwise. If the meter indicates a clockwise movement, the motor leads connected to L1, L2, and 
L3 of the meter are T1, T2, and T3, respectively. If the meter indicates a counterclockwise move-
ment, swap any two connects between the meter and motor. Then retest.

• 

: Press the 

SELECT

 button momentarily to select Phase function. Connect the meter to the 

phases as described in the “Settings Table” section of this manual. If the meter indicates a 
clockwise movement, the phases connected to L1, L2, and L3 of the meter are L1, L2, and L3, 
respectively. If the meter indicates a counterclockwise movement, swap any two connects between 
the meter and phases. Then retest.

www.

.com

[email protected]

1.800.561.8187

Содержание CM-1360

Страница 1: ...n comprendre toutes les instructions et les informations sur la s curit de ce manuel avant d utiliser ou de proc der l entretien de cet outil Vor Bedienung oder Wartung dieses Messger tes bitte alle A...

Страница 2: ...Mode Zero Mode Intelligent Auto Power Off Automatic ranging Backlit LCD Safety Safety is essential in the use and maintenance of Greenlee tools and equipment This instruction manual and any markings o...

Страница 3: ...ged Clamp meter test leads or any other clamp accessory when used to make a measurement create a System The System is rated for CAT III 1000 V or CAT IV 600 V when using the test leads or accessories...

Страница 4: ...generates electromagnetic interference can result in unstable or inaccurate readings Failure to observe these warnings could result in severe injury or death Electric shock hazard Do not change the me...

Страница 5: ...ve common or ground input terminal L1 input for motor and phase rotation 8 Refer to explanation under Using the Features 9 Jaw lever 10 Keep hand or ngers below the dashed line during operation 11 Jaw...

Страница 6: ...7 Relative zero function is enabled 18 Polarity indicator 19 VFD AC measurement with lter for accuracy on variable frequency drives 20 AC measurement is selected 21 AC DC measurement is selected 22 DC...

Страница 7: ...rmal mode In zero mode the value on the LCD when the button is pressed becomes the offset As the input value changes the offset is subtracted from the actual value This modi ed value is shown on the L...

Страница 8: ...ent categories III and IV These test leads include a cap that must be in place when used in measurement category III or IV applications Failure to observe this warning could result in severe injury or...

Страница 9: ...RMS Value 100 100 100 100 Average Value 90 100 87 64 Crest Factor j 1 414 1 1 73 2 The crest factor is the ratio of the peak value to the RMS value it is represented by the Greek letter j AC DC True R...

Страница 10: ...e selector to this symbol These icons appear on the display Connect the red lead to Connect the black lead to ALL MODELS Voltage AC V COM Voltage DC V COM Current AmpTip AC A N A N A Current AC A N A...

Страница 11: ...400 0 Hz DC bias must be less than 50 of the Sine RMS value Accuracy of Frequency Range Display Range Accuracy xx xx 1 0 0 05 Hz xxx x 1 0 0 5 Hz Voltage Measurement V Hz EF VFD SELECT SELECT VFD AC V...

Страница 12: ...for adjacent current carrying conductors is 0 02 A A AmpTip DC Current CM 1560 and CMI 1000 only Range Accuracy Range Accuracy 60 00 A 0 00 A to 3 99 A 1 5 0 15 A 4 00 A to 60 00 A 1 5 0 05 A Induced...

Страница 13: ...st factor 1 4 1 at full scale and 2 8 1 at half scale Induced error for adjacent current carrying conductors is 0 05 A A For any measurement when the conductor is not positioned on the center of the j...

Страница 14: ...Threshold Between 10 and 250 Response Time Approximately 32 ms Capacitance Measurement Capacitance Range Accuracy 200 0 F 2 0 0 4 F 2500 F 2 0 4 F For lm capacitors capacitors with negligible dielect...

Страница 15: ...F 1 0 2 F Thermocouples supplied with meter meet standard JIS C 1602 1981 Electric Field A 10 mm 0 4 B SELECT A Non contact OR B Contact precision measurement Non contact EF Detection Typical Voltage...

Страница 16: ...digits In an RF eld of 3V m all other modes and models not speci ed above Total Accuracy Speci ed Accuracy 20 digits Safety Double insulation per UL IEC EN61010 1 Ed 3 IEC EN61010 2 033 Ed 1 CAN CSA C...

Страница 17: ...the main circuit breaker panels of a building s electrical system Measurement Category IV Primary supply level Overhead lines and other cable systems Some examples include cables meters transformers...

Страница 18: ...to de veri caci n revise si las bater as est n bajas y es necesario reemplazarlas Garantie vie limit e La soci t Greenlee Textron Inc garantit l acheteur d origine de ces produits que ces derniers ne...

Отзывы: