Greenlee CM-1360 Скачать руководство пользователя страница 5

CM-1360 • CM-1560 • CMH-1000 • CMI-1000

5

Identification

  1. Antenna for non-contact EF detection

  2. Jaw center indicator for best current accuracy; polarity indicator for DC amps

  3. Selects a function or turns power off

 4. LCD

  5. Input jack for phase and motor rotation functions only

  6. Positive input terminal; L2 input for motor and phase rotation

  7. Negative, common, or ground input terminal; L1 input for motor and phase rotation

  8. Refer to explanation under “Using the Features.”

 9. Jaw lever

10.  Keep hand or fingers below the dashed line during operation.

11. Jaw

12.  Center indicator for AmpTip™ function

Symbols on the Unit

Warning—Read the instruction manual

Warning—Risk of electric shock

Earth ground

Double insulation

AC (alternating current)

DC (direct current)

Application around or removal from hazardous live conductors is permitted.

12

11

1

2

3

4

6

5

9

10

8

7

www.

.com

[email protected]

1.800.561.8187

Содержание CM-1360

Страница 1: ...n comprendre toutes les instructions et les informations sur la s curit de ce manuel avant d utiliser ou de proc der l entretien de cet outil Vor Bedienung oder Wartung dieses Messger tes bitte alle A...

Страница 2: ...Mode Zero Mode Intelligent Auto Power Off Automatic ranging Backlit LCD Safety Safety is essential in the use and maintenance of Greenlee tools and equipment This instruction manual and any markings o...

Страница 3: ...ged Clamp meter test leads or any other clamp accessory when used to make a measurement create a System The System is rated for CAT III 1000 V or CAT IV 600 V when using the test leads or accessories...

Страница 4: ...generates electromagnetic interference can result in unstable or inaccurate readings Failure to observe these warnings could result in severe injury or death Electric shock hazard Do not change the me...

Страница 5: ...ve common or ground input terminal L1 input for motor and phase rotation 8 Refer to explanation under Using the Features 9 Jaw lever 10 Keep hand or ngers below the dashed line during operation 11 Jaw...

Страница 6: ...7 Relative zero function is enabled 18 Polarity indicator 19 VFD AC measurement with lter for accuracy on variable frequency drives 20 AC measurement is selected 21 AC DC measurement is selected 22 DC...

Страница 7: ...rmal mode In zero mode the value on the LCD when the button is pressed becomes the offset As the input value changes the offset is subtracted from the actual value This modi ed value is shown on the L...

Страница 8: ...ent categories III and IV These test leads include a cap that must be in place when used in measurement category III or IV applications Failure to observe this warning could result in severe injury or...

Страница 9: ...RMS Value 100 100 100 100 Average Value 90 100 87 64 Crest Factor j 1 414 1 1 73 2 The crest factor is the ratio of the peak value to the RMS value it is represented by the Greek letter j AC DC True R...

Страница 10: ...e selector to this symbol These icons appear on the display Connect the red lead to Connect the black lead to ALL MODELS Voltage AC V COM Voltage DC V COM Current AmpTip AC A N A N A Current AC A N A...

Страница 11: ...400 0 Hz DC bias must be less than 50 of the Sine RMS value Accuracy of Frequency Range Display Range Accuracy xx xx 1 0 0 05 Hz xxx x 1 0 0 5 Hz Voltage Measurement V Hz EF VFD SELECT SELECT VFD AC V...

Страница 12: ...for adjacent current carrying conductors is 0 02 A A AmpTip DC Current CM 1560 and CMI 1000 only Range Accuracy Range Accuracy 60 00 A 0 00 A to 3 99 A 1 5 0 15 A 4 00 A to 60 00 A 1 5 0 05 A Induced...

Страница 13: ...st factor 1 4 1 at full scale and 2 8 1 at half scale Induced error for adjacent current carrying conductors is 0 05 A A For any measurement when the conductor is not positioned on the center of the j...

Страница 14: ...Threshold Between 10 and 250 Response Time Approximately 32 ms Capacitance Measurement Capacitance Range Accuracy 200 0 F 2 0 0 4 F 2500 F 2 0 4 F For lm capacitors capacitors with negligible dielect...

Страница 15: ...F 1 0 2 F Thermocouples supplied with meter meet standard JIS C 1602 1981 Electric Field A 10 mm 0 4 B SELECT A Non contact OR B Contact precision measurement Non contact EF Detection Typical Voltage...

Страница 16: ...digits In an RF eld of 3V m all other modes and models not speci ed above Total Accuracy Speci ed Accuracy 20 digits Safety Double insulation per UL IEC EN61010 1 Ed 3 IEC EN61010 2 033 Ed 1 CAN CSA C...

Страница 17: ...the main circuit breaker panels of a building s electrical system Measurement Category IV Primary supply level Overhead lines and other cable systems Some examples include cables meters transformers...

Страница 18: ...to de veri caci n revise si las bater as est n bajas y es necesario reemplazarlas Garantie vie limit e La soci t Greenlee Textron Inc garantit l acheteur d origine de ces produits que ces derniers ne...