Greenlee CM-1360 Скачать руководство пользователя страница 18

 

"O*40$PNQBOZt(SFFOMFF5FYUSPO*ODJTBTVCTJEJBSZPG5FYUSPO*OD

Lifetime Limited Warranty

Greenlee Textron Inc. warrants to the original purchaser of these goods for use that these  products 
will be free from defects in workmanship and material for their useful life, excepting normal wear and 
abuse. This warranty is subject to the same terms and conditions contained in Greenlee Textron Inc.’s 
standard one-year limited warranty.

For items not covered under warranty (such as items dropped, abused, etc.), a repair cost quote is 
available upon request.

Note:  Prior to returning any test instrument, please check replaceable  batteries or make sure the 
battery is at full charge.

Garantía limitada válida durante la vida útil del producto

Greenlee Textron Inc. le garantiza al comprador original de estos bienes de uso, que los mismos 
estarán libres de defectos de materiales y fabricación durante su vida útil, excepto en el caso de que 
sean maltratados o hayan sufrido el deterioro normal. Esta garantía está sujeta a los mismos términos 
y condiciones de la garantía estándar limitada válida por un año, otorgada por Greenlee Textron Inc.

Puede obtener, previa solicitud, una cotización de precios de reparación para aquellos artículos que 
no están cubiertos bajo esta garantía (los que se han dejado caer o han sido maltratados).

Aviso: Antes de devolver un instrumento de verificación, revise si las baterías están bajas y es 
necesario reemplazarlas.

Garantie à vie limitée

La société Greenlee Textron Inc. garantit à l’acheteur d’origine de ces produits que ces derniers ne 
comportent aucun défaut d’exécution ou de matériau pour la durée de leur vie utile, sauf l’usure 
normale. Cette garantie est assujettie aux mêmes conditions que celles contenues dans les modalités 
et conditions de la garantie limitée standard d’un an de Greenlee Textron Inc.

Lorsque les articles ne sont pas protégés par une garantie (comme si l’appareil tombe, s’il est soumis 
à un usage abusif, etc.), une soumission pour le prix de réparation sera présentée sur demande.

Remarque : Avant de renvoyer un appareil de mesure, veuillez vérifier les piles remplaçables ou vous 
assurer que la batterie est  complètement chargée.

Lebenslange beschränkte Garantie

Greenlee Textron Inc. garantiert dem Erstkäufer dieser Produkte, dass sie unter Ausschluss von 
normalem Verschleiß oder Missbrauch für den Zeitraum ihrer Nutzungsdauer frei von Bearbeitungs- 
und Materialfehlern sind. Diese Garantie unterliegt denselben Bedingungen, die auch für die 
standardmäßige beschränkte Einjahresgarantie von Greenlee Textron Inc. gelten.

Bei Geräten ohne Garantieschutz (z.B. heruntergefallene oder missbrauchte Produkte) kann auf 
Anfrage ein Kostenvoranschlag für die Reparatur erstellt werden.

Hinweis:  Bitte prüfen Sie vor dem Einsenden des Geräts die austauschbaren Batterien bzw. stellen 
Sie sicher, dass die Batterie vollständig geladen ist.

www.

.com

[email protected]

1.800.561.8187

Содержание CM-1360

Страница 1: ...n comprendre toutes les instructions et les informations sur la s curit de ce manuel avant d utiliser ou de proc der l entretien de cet outil Vor Bedienung oder Wartung dieses Messger tes bitte alle A...

Страница 2: ...Mode Zero Mode Intelligent Auto Power Off Automatic ranging Backlit LCD Safety Safety is essential in the use and maintenance of Greenlee tools and equipment This instruction manual and any markings o...

Страница 3: ...ged Clamp meter test leads or any other clamp accessory when used to make a measurement create a System The System is rated for CAT III 1000 V or CAT IV 600 V when using the test leads or accessories...

Страница 4: ...generates electromagnetic interference can result in unstable or inaccurate readings Failure to observe these warnings could result in severe injury or death Electric shock hazard Do not change the me...

Страница 5: ...ve common or ground input terminal L1 input for motor and phase rotation 8 Refer to explanation under Using the Features 9 Jaw lever 10 Keep hand or ngers below the dashed line during operation 11 Jaw...

Страница 6: ...7 Relative zero function is enabled 18 Polarity indicator 19 VFD AC measurement with lter for accuracy on variable frequency drives 20 AC measurement is selected 21 AC DC measurement is selected 22 DC...

Страница 7: ...rmal mode In zero mode the value on the LCD when the button is pressed becomes the offset As the input value changes the offset is subtracted from the actual value This modi ed value is shown on the L...

Страница 8: ...ent categories III and IV These test leads include a cap that must be in place when used in measurement category III or IV applications Failure to observe this warning could result in severe injury or...

Страница 9: ...RMS Value 100 100 100 100 Average Value 90 100 87 64 Crest Factor j 1 414 1 1 73 2 The crest factor is the ratio of the peak value to the RMS value it is represented by the Greek letter j AC DC True R...

Страница 10: ...e selector to this symbol These icons appear on the display Connect the red lead to Connect the black lead to ALL MODELS Voltage AC V COM Voltage DC V COM Current AmpTip AC A N A N A Current AC A N A...

Страница 11: ...400 0 Hz DC bias must be less than 50 of the Sine RMS value Accuracy of Frequency Range Display Range Accuracy xx xx 1 0 0 05 Hz xxx x 1 0 0 5 Hz Voltage Measurement V Hz EF VFD SELECT SELECT VFD AC V...

Страница 12: ...for adjacent current carrying conductors is 0 02 A A AmpTip DC Current CM 1560 and CMI 1000 only Range Accuracy Range Accuracy 60 00 A 0 00 A to 3 99 A 1 5 0 15 A 4 00 A to 60 00 A 1 5 0 05 A Induced...

Страница 13: ...st factor 1 4 1 at full scale and 2 8 1 at half scale Induced error for adjacent current carrying conductors is 0 05 A A For any measurement when the conductor is not positioned on the center of the j...

Страница 14: ...Threshold Between 10 and 250 Response Time Approximately 32 ms Capacitance Measurement Capacitance Range Accuracy 200 0 F 2 0 0 4 F 2500 F 2 0 4 F For lm capacitors capacitors with negligible dielect...

Страница 15: ...F 1 0 2 F Thermocouples supplied with meter meet standard JIS C 1602 1981 Electric Field A 10 mm 0 4 B SELECT A Non contact OR B Contact precision measurement Non contact EF Detection Typical Voltage...

Страница 16: ...digits In an RF eld of 3V m all other modes and models not speci ed above Total Accuracy Speci ed Accuracy 20 digits Safety Double insulation per UL IEC EN61010 1 Ed 3 IEC EN61010 2 033 Ed 1 CAN CSA C...

Страница 17: ...the main circuit breaker panels of a building s electrical system Measurement Category IV Primary supply level Overhead lines and other cable systems Some examples include cables meters transformers...

Страница 18: ...to de veri caci n revise si las bater as est n bajas y es necesario reemplazarlas Garantie vie limit e La soci t Greenlee Textron Inc garantit l acheteur d origine de ces produits que ces derniers ne...