General Information

“UL CLASSIFIED (see complete marking on 
product)”
“UL CLASSIFIED to Canadian safety standards 

(see complete marking on product)”
 

Standard 555C (Listing #R13446)

These installation instructions show recommended 
installation procedures. These or other installation 
methods may be followed subject to the approval of the 
authority having jurisdiction.
Model CRD-310, 320, 350, 360, 310L, 320L, 310WT 
and 700 are specific sizes of Greenheck’s model  
DFD-350 dampers equipped with hardware to facilitate 
installation with Greenheck model SP ceiling exhaust 
fans.
The CRD-3xx(L, WT) series and CRD-700 dampers are 
classified to function as a heat barrier in air handling 
penetrations through fire resistive membrane ceilings. 
They are intended to maintain the fire resistive integrity 
of the ceiling. They can only be installed in conjunction 
with the SP fan models shown and cannot be installed 
alone.

NOTE:

  Motors for fan models used in conjunction with 

CRD shall be equipped with thermal cut-off fuse 
control.

Receiving and Handling

Upon receiving dampers, check for both obvious 
and hidden damage. If damage is found, record all 
necessary information on the bill of lading and file 
a claim with the final carrier. Check to be sure that 
all parts of the shipment, including accessories, are 
accounted for.
Dampers must be kept dry and clean. Indoor storage 
and protection from dirt, dust and the weather is 
highly recommended. Do not store at temperatures in 
excess of 100°F (38°C).

Table of Contents

General Information  ............................................. 2
Plaster Flange Application .................................... 3
Damper Installation to a SP Fan  .......................... 4
Installation .........................................................5-7
  •  ETL - Wood Construction  ............................. 5
  • UL/cUL - 1 Hour Combustible Floor/Ceiling . 6
  • UL/cUL - 3 Hour Non -Combustible Floor/ 
     Ceiling ............................................................ 7
Maintenance ......................................................... 8
Troubleshooting .................................................... 8

Safety Warning

Improper installation, adjustment, alteration, service 
or maintenance can cause property damage, injury 
or death. Read the installation, operating, and 
maintenance instructions thoroughly before installing 
or servicing this equipment.

CRD Series for SP Fans

2

®

Содержание CRD-3 Series

Страница 1: ...D 700 Series for SP Fans Installation Operation and Maintenance Manual Please read and save these instructions for future reference Read carefully before attempting to assemble install operate or main...

Страница 2: ...Motors for fan models used in conjunction with CRD shall be equipped with thermal cut off fuse control Receiving and Handling Upon receiving dampers check for both obvious and hidden damage If damage...

Страница 3: ...he assembly around the damper in the orientation shown in Figure 1 Connect the open ends of the flange together 2 Align the edge of the plaster flange with the edge of the damper frame Clamp the flang...

Страница 4: ...B200 CRD 320 CRD 320L CRD 320 41 2 155 8 141 2 123 8 SP A50 SP A70 SP A90 SP A110 SP A125 SP A190 CRD 310WT CRD 310 CRD 310L CRD 310 WT CRD 310 51 2 145 8 135 8 111 8 SP A250 SP A290 SP A390 SP A200...

Страница 5: ...with the unit 2 The fan damper assembly is to be attached to the trusses using 2 1 in x 1 in x 16 ga 25mm x 25mm x 1 5mm or 2 11 4 in x 1 in x 20 ga 32mm x 25mm x 1mm mounting angles Attach mounting...

Страница 6: ...minimum of 2 8 screws or 5 32 in 4mm diameter steel rivets Note Make sure the fasteners do not interfere with the damper operation 3 Install the fan damper assembly with attached mounting angles betwe...

Страница 7: ...when using with a suspended ceiling UL cUL Installation 3 Hour Non Combustible Floor Ceiling Assemblies SP Fan 10 32 Threaded Steel Rod Hanging Vibration Isolation Ceiling Radiation Damper Fire Rated...

Страница 8: ...eals Adjust frame such that it is square and plumb Screws in damper linkage Damper installed too far into wall Move out to line as designated on damper label Contaminants on damper Clean with a non oi...

Отзывы: