Version 4.37 • CE • ALIS Tube Lamp
21 May 2019
3.1 ALIS bus termination
Route the ALIS Bus to the ALIS Power Hub location, paying attention to the section 6. of this manual.
ALIS Dimmer Model IPDI110
. Strip the ends of the ALIS Bus to 5mm (0.2 inch) of exposed conductor,
ensuring there is not any conductor loss.
Attach the ALIS Bus to the Bus Connector into the screw terminals provided, as shown below. Ensure there are
no frayed copper strands.
ALIS Dimmer Model IPDI230
. Strip the ends of the ALIS Bus to 5mm (0.2 inch) of exposed conductor,
ensuring there is not any conductor loss.
Attach the ALIS Bus to the Bus Connector into the screw terminals provided, as shown below. Ensure there are
no frayed copper strands.
Note: The cable must be connected to the pin 1 and 2.
ALIS Dimmer Model AGL0004
. Strip the outer insulation of the ALIS Bus to 30mm (1
¼
inches) taking care not
to damage the inner insulation. Strip the ends of the ALIS Bus inner insulation to 8mm (0.3 inch) of exposed
conductor, ensuring there is not any conductor loss.
Slide the orange connector cover labelled
PLUG
over the ALIS Bus. Attach the ALIS Bus to the orange connector
PLUG
into the screw terminals provided, as shown below. Ensure there are no frayed copper strands. Slide and
fix the cover in place over the connector.
Remove the existing ALIS Bus connector from the ALIS Power Hub and cut off the remaining exposed copper
conductor. Slide the orange connector cover labelled
SOCKET
over the ALIS Power Hub ALIS Bus. Strip the outer
insulation of the ALIS Bus to 30mm (1¼ inches) taking care not to damage the inner insulation. Strip the ends of
the ALIS Bus inner insulation to 8mm (0.3 inch) of exposed conductor, ensuring there is not any conductor loss.
Attach the ALIS Power Hub ALIS Bus to the orange connector
SOCKET
into the screw terminals provided, as shown
below. Ensure there are no frayed copper strands. Side and fix cover in place over the connector.