Page
10
of
28
Version 4.37 • CE • ALIS Tube Lamp
21 May 2019
1.3 ALIS Dimmer mounting
The ALIS Dimmer must be mounted within the same enclosure as the ALIS Power Hub, either horizontally or
vertically in close proximity to the ALIS Power Hub. If this is not possible then the ALIS Dimmer enclosure must
be used, mounted away from all combustible materials, sources of heat and out of direct sunlight.
ALIS Power Hub Panel
2 Channel x 500W
ALIS Dimmer
in enclosure
ALIS Power Hub Panels
(shown with DTD Controller providing 0-10V input)
Please note: Diagrams above for illustration purposes.
Both the ALIS Power Hub and ALIS Dimmer must be mounted within a dry and dust free
location acceptable to local wiring regulations. If this is not possible then they must be
housed within a suitably sealed enclosure as per local wiring regulations. Due to the heat
generated by the ALIS Power Hub please contact
for further
advice if required.
2.
ALIS Tube connection (lengths 0.6m, 0.9m and 1.2m)
Reference the lamp positioning information, found within the lighting design plan in conjunction with section 5.0
of this manual. If there is not any positioning information available, then contact your supplier for further advice.
Take note of the lamp position and place the first ALIS Tube as follows.
1.
Clip the first ALIS Tube onto the catenary wire carrier utilising the two channels provided at either end.
Place a fixing clip over each channel of the ALIS Tube to hold it in place.