RANGE XT80/160 – TECHNICAL DOCUMENTATION
Page 8
In case of modification, the design office shall comply as much as possible with the following
specifications:
• The height of the concrete base must be calculated and adapted according to these various
parameters to ensure a rest in an off-freeze zone;
• Concrete base thicknesses must not be less than 20 cm (if watertight, 25 cm and MPKC concrete
or equivalent);
• The concrete base must be reinforced;
• The bottom of the niche must have a drain for water discharge; (avoid any kind of water flow)
• The dimensions indicated for the center niche (width x depth) represent a minimum to ensure
the introduction of the power cable;
• The fixation points for fixing the charging station to the concrete base can be sealed through
chemical process and the holes must be at least 6 cm away from the edges.
2.1.7 Exclusion of liability clause
Green Motion SA delivered indicative information to the good execution of the concrete base. It won’t
be responsible, in any case, of the dimensioning, geometry and implantations of the base, this point of
the unique skills and responsibility of the civil engineering office mandated by the client to study carefully
each implantation project.