RANGE XT80/160 – TECHNICAL DOCUMENTATION
Page 28
4)
Adjust the return power of the cables (1 person):
a)
To loosen the rope, it is possible to manually loosen the lateral adjustment screw by quarter
turn, then test (tensioning the steel rope is more restrictive).
b)
To tension the steel rope, tighten the adjustment screw using a medium-sized adjustable
wrench or water pump pliers.
c)
As a tension measurement point, we can use the distance between the axis of the lower
mobile pulley and the axis of the lower pulley.
d)
Before taking the measurement, check that the cable loop is at the top.
e)
The min / max reference measurement is between 25cm and 27cm.
-
With 25cm the cable is rather hard to deploy but it fits by itself.
-
With 27cm the cable is easier to deploy but does not come back completely.