U-Match Series Duct Type Unit
43
Check items
Possible events due to improper insta
l
lation
Is the voltage consistent with that
stated on the nameplate?
The unit may fail or its components may get
burned.
Are the wires and pipes installed
correctly?
The unit may fail or its components may get
burned.
Has the unit been safely
grounded?
Risk of electric leakage.
Do the specifications of wires
comply with the requirement?
The unit may fail or its components may get
burned.
Is there any obstacle blocking
the air inlet and outlet of the
indoor unit?
Cooling capacity may become unsatisfactory.
Have you recorded the length of
refrigerant pipe and the
refrigerant charging amount?
The refrigerant charging amount can’t be
controlled.
3.5 Test Running
Preparation before connecting the power.
(1) Power must not be connected if the installation work is not completed.
(2) Control circuit is correct and all the wires are firmly connected.
(3) Cut-off valves of the gas pipe and liquid pipe are open.
(4) The inside of the unit should be clean. Take irrelevant objects out if there is
any.
(5) After checking, re-install the front side plate.
Operation after connecting the power.
(1) If all the above works are finished, power on the unit.
(2) If the outside temperature is more than 30°C, heating mode can't be enabled.
(3) Make sure the indoor and outdoor units can run normally.
(4) If there's sound of liquid shock when the compressor is running, then stop the
air conditioner immediately. Wait until the electric heating belt is heated
enough, and then restart the air conditioner.
(5) Feel the air flow of the indoor unit to see if it is normal.
(6) Press the swing button or speed control button on remote control or wired
control to see if the fan can run normally.