Window type conditioner is so valuable and the improper installation of it will cause a lot of damage! Please associate the professional
technician to install the unit and don’t install it by yourself.Otherwise, we are not responsible for the damage like this.
● The condensation water must be drained away conveniently.
● Install air conditioner unit far away from TV set or radioetc. to avoid disturbing video or voice.
● In salt and coastal area or place where is near thermal springs and polluted by sulphurous gas, or other special areas, please contact
the seller before use.
● Avoid a place where is possible for inflammable gas to leak out.
● Avoid other heat sources or direct sun light.
● Avoid a place where is easy for children to touch.
● Don't use the unit in the immediate surrondings of a laundry,a bath,a shower or a swimming pool.
● For window type air conditioner with remote control, install in a location where is strong electromagnetic disturbance, you should
contact the seller in advance to avoid the malfunction in use.
● Choose a location where there are no any obstacle surrounding the unit, and the plug is accessible.
● Prepare the installation hole slightly bigger than unit size.
● Choose the installation space according to outline dimension diagram.(Please refer to the chapter 3)
8.Installation
8.1 Installation Precaution
8.2 Location
8.3 How to Install
8.4 Installation Procedure
8.5 Installation Assistance
1) Remove the sticker from the front panel.
2) Put the unit into the installation hole.
● When installing, make sure the unit is slanted downward to the back to
minimize the nosie and vibration of operation. (Slant by 6-10mm.) (See the
right figure)
● Make sure the installation place is strong enough to minimize the noise and
vibration of operation.
3) Fill the gaps in the cabinet with sponge or foam.
1) Use iron support
The installation hole should be strong enough to support the air conditioner. If
it cannot, iron support has to be used outdoors.Iron support should be fixed on
the building (Shown at right figure.)
2) Use sunshade board
Air conditioner should avoid anything to be dropped into it and avoid direct
sunshine. If there is no cover on it, you should contact the seller for installing
the sunshade board. When installing the sunshade board, don’t let it block the
air inlet at the side grille.
6-10mm
Horizontal line
Wall
Support
Wooden frame
Rubber plate
Horizontal line
Sunshade
baffle
6-10mm