Service Manual
Technical Information
15
Model
GJH09AK-K6NRNR1A
GJH09AK-K6NRNB3C
GJH09AK-K6NRNG2A
GJH12AG-K6NRNG1A
Product code
CC053010800
CC053029800
CC053031400
CC053032700
Power
Supply
Rated Voltage
V~
220-240
220-240
Rated Frequency
Hz
50
50
Phases
1
1
Cooling Capacity
W
2800
3900
Heating Capacity
W
2450
3600
Cooling Power Input
W
840
1180
Heating Power Input
W
740
1060
Cooling Power Current
A
3.69
5.13
Heating Power Current
A
3.25
4.53
Rated Input
W
1100
1600
Rated Current
A
5
7.5
Air Flow Volume(H/M/L)
m
3
/h
480/430/380
660/610/560
Dehumidifying Volume
L/h
1.0
1.5
EER
W/W
3.33
3.31
COP
W/W
3.33
3.4
SEER
W/W
/
/
HSPF
W/W
/
/
Application Area
m
2
12-18
16-24
Fan Motor Speed(H/M/L)
rpm
930/870/810
900/830/760
Output of Fan Motor
W
45
100
Fan Motor RLA
A
0.43
0.73
Fan Motor Capacitor
μF
3.5
4
Climate Type
T1
T1
Isolation
I
I
Moisture Protection(Outdoor)
IPX4
IPX4
Permissible Excessive Operating Pressure for the
Discharge Side
MPa
4.3
4.3
Permissible Excessive Operating Pressure for the
Suction Side
MPa
2.5
2.5
Dimension (WXHXD)
mm
560X375X668
660X428X700
Dimension of Carton Box (LXWXH)
mm
763X620X410
790X736X490
Dimension of Package (LXWXH)
mm
766X623X425
793X739X505
Net Weight
kg
40
51
Gross Weight
kg
43.5
55
Refrigerant
R32
R32
Refrigerant Charge
kg
0.6
0.86