Intelligent Controller
17
Fig. 7.11 Server setting page
Settable parameters:controller IP address (IP address setting: master unit No.
can’t be 0 for all; 0 for all means the entire network, e.g. 192.168.1.0; master unit No.
can’t be 1 for all; 1 for all means the broadcast address, e.g. 192.168.1.255, the
user is not recommended for setting, you might fail to visit the controller interface
after setting), controller subnet mask, defaulted gateway of controller, equipment
name, equipment ID(0~255), network type, service IP, service port (defaulted value
is 6687, the Intelligent Remote Eudemon version is below the value of 6688 input
in version V2.0). The user shall configure it based on personal demand. After setting,
click the arrow, the interface will pop “Restart controller”, select “Yes” to restart the
controller immediately, select “Cancel” to return to the configuration interface of
controller.