23
D Series Modular Air-cooled Scroll Chillers
Service Manual
6SHFL¿FDWLRQRI3RZHU&RUGDQG$LU6ZLWFK
Model
Power Supply
Min. sectional area of the power cable (mm
2
)
Capability of the
Air Switch(A)
Live Line
Neutral Line
Earth Line
LSQWRF65M/NaD-M
380-415V,3Ph,50Hz
16
4
16
63
LSQWRF80M/NaD-M
25
4
16
80
LSQWRF130M/NaD-M
50
4
25
125
LSQWRF160M/NaD-M
70
4
35
160
Notes:
a.The specifications of the minimal size of the neural line should be 4mm
2
, that is, the selected size of the
neutral line should be equal to or larger than 4mm
2
.
b.The specifications of the breaker and power cable listed in the table above are determined based on the
PD[LPXPSRZHUPD[LPXPDPSVRIWKHXQLW
c.
7KHVSHFL¿FDWLRQVRIWKHSRZHUFDEOHOLVWHGLQWKHWDEOHDERYHDUHDSSOLHGWRWKHFRQGXLWJXDUGHGPXOWLZLUH
copper cable (like, JYV copper cable, consisting of PV insulated wires and a PVC cable jacket) used at 40
ć
and resistible to 90
ć
VHH,(&,IWKHZRUNLQJFRQGLWLRQFKDQJHVWKH\VKRXOGEHPRGL¿HG
according to the related national standard.
d.
7KHVSHFL¿FDWLRQVRIWKHEUHDNHUOLVWHGLQWKHWDEOHDERYHDUHDSSOLHGWRWKHEUHDNHUZLWKWKHZRUNLQJWHPSHUDWXUH
at 40
ć
,IWKHZRUNLQJFRQGLWLRQFKDQJHVWKH\VKRXOGEHPRGL¿HGDFFRUGLQJWRWKHUHODWHGQDWLRQDOVWDQGDUG
8.4 WIRING DIADRAM
(1). LSQWRF65M/NaD-M
The diagram is only for reference and the circuit diagram attached on the unit prevails.
ТОО "Everest climate" г. Алматы, Варламова 1а, тел. +7 727 230 00 10, e-mail: [email protected], сайт: www.aircon.kz