background image

 
 

23 

 
 

7.14 How to replace batteries 

 

 
 
 
1. Slide down the battery cover of the remote 

controller and remove the old batteries. 

2. Replace with two new ones (be careful 

about correctness of the polarities) 

3. Re-attach the cover. 

 

NOTE

 

  Do not mix new and used or different types 

of batteries for use. 

  Take out the batteries if the wireless remote 

controller will not be in use for a long time. 

  The operation of the remote controller must 

be within 10 meters for reception. 

  Battery life is about one year. 

  Remote controller should be more than one 

meter's distance to TV or Hi-Fi 
equipments. 

 
 
 
 

2. Insert 2 AAA batteries   

 
 
 
 
 
 
 
 
 

 

1. Remove the cover 
3. Re-attach the cover 

Содержание KFR-32GW/NJ1F

Страница 1: ...the information of our product technology Technical Service Department Gree Electric Appliances Inc Of Zhuhai March 2004 Table of Contents 1 Summary and features 1 2 Specifications and technical para...

Страница 2: ...1 1 Summary and features Models Remark...

Страница 3: ...3 2 Specifications and technical parameters...

Страница 4: ...4...

Страница 5: ...he wireless remote controller the run indicator is on green This light blinks while defrosting Air in Outdoor unit Air out Front panel Filter Purifier filter Operation switch Electric box cover LCD Gu...

Страница 6: ...dimension 4 1 Outline and installation dimension of indoor unit Air inlet hole Right piping hole flag Piping hole flag Liquid crystal display and reception window Air inlet hole Rear view Left Ceilin...

Страница 7: ...7 4 2 Outline and installation dimension of outdoor unit Unit mm Above 60cm Bolt Nut Spanner...

Страница 8: ...anger With the help of axial flow fan the gas transfers its latent heat into outdoor air and becomes refrigerant liquid The liquid is throttled by throttling device and changes into low temperature an...

Страница 9: ...9 6 Electrical circuit diagram These circuit diagrams are subject to change without notice Please refer to the one supplied with the unit...

Страница 10: ...amb Set temperature Tset Tset 2 3 min Compressor Outdoor fan COOL mode will act Keep running in original state COOL mode will stop Indoor fan Run at the set speed Run Stop In this mode the reversal va...

Страница 11: ...me and the indoor fan will run in anti cold wind mode If Tset 2 Tamb T set 5 the unit will keep running in the original mode If Tamb Tset 5 the compressor will stop the outdoor fan will delay 30sec to...

Страница 12: ...e hidden set temperature is 25 If T amb Tset 2 the compressor and outdoor fan will stop the indoor fan will run at the set speed if Tset 2 Tamb Tset 1 the unit will keep running in the original mode I...

Страница 13: ...ed and the guide louver runs in SWING mode The backlight is turned on If this is remote signal the unit will run according to remote signal When the wireless remote controller is used to select COOL m...

Страница 14: ...ssor s running frequency The indoor fan run at low speed in FAN mode 4 Swing option Press the SWING button to control its ON and OFF Swing can only be activated when indoor fan is running 5 Buzzer Whe...

Страница 15: ...louver starts to swing at the stated angle and stops when it is pressed again FAN button Each time this button is pressed fan speed will change in the following order AUTO FAN TEMP button Each time is...

Страница 16: ...ribed below We are sorry for the inconvenience LCD It shows all selected contents SLEEP button Press this button once to set SLEEP operation and press it once again to exit SLEEP operation TIMER OFF b...

Страница 17: ...perature is between 1 and 2 5 the compressor will stop the outdoor fan will stop after 30sec and the indoor fan will run at low speed If the fan is set at AUTO mode microcomputer of the remote control...

Страница 18: ...erature is between 1 and 2 5 the compressor will stop the outdoor fan will stop after 30sec and the indoor fan will run at low speed If the fan is set at AUTO mode microcomputer of the remote controll...

Страница 19: ...ill stop after 30sec and the indoor fan will stop immediately and start running at low speed after 5min In this mode the temperature setting range is 16 30 At this time the LCD appears green 3 Press t...

Страница 20: ...standard temperature setting of HEAT mode is 20 1 After power on press the 1 0 button to set the air conditioner running 2 Press the MODE button to select AUTO mode and the microcomputer will select...

Страница 21: ...operation mode Under turn off state press the TIMER ON button to set the timed turn on in range of 0 to 24 hours Under turn on state press the TIMER OFF button to set the timed turn off in range of 0...

Страница 22: ...rature will be decreased by 1 in the first hour and decreased by 2 in the second hour Then the unit will run at this set temperature 4 Press the FAN button to set fan speed 3 Press the SWING button an...

Страница 23: ...E Do not mix new and used or different types of batteries for use Take out the batteries if the wireless remote controller will not be in use for a long time The operation of the remote controller mus...

Страница 24: ...off the three pieces of tapping screws Then use screwdriver to push up the clasp that is fixed into the panel body at its back inward and take off the front panel assy As shown in Fig 8 2 Front panel...

Страница 25: ...r motor and stepping motor etc Then unclench the clasp that fixes the electric box on the rear case to take out the electric box As shown in Fig 8 4 Fig 8 4 8 1 3 Disassembling the water tray assy Scr...

Страница 26: ...apping screws that fix the rear clamp and unclench the clasp that fixes it into the rear case to take off the rear clamp As shown in Fig 8 8 Screw off the tapping screws that fix the evaporator on the...

Страница 27: ...the fixing screws on the right inside the cross flow fan with screwdriver to take out the motor enclosed by plastic Pay attention to the angle when the motor is installed As shown in Fig 8 12 Screw ou...

Страница 28: ...ew off the 5 pieces of screws on the front side and 1 on the left side and take off the front panel with strength As shown in Fig 8 15 Fig 8 15 8 2 2 Disassembling the rear grill and right side plate...

Страница 29: ...th strength As shown in Fig 8 18 Fixing nut Fig 8 18 Screw off the 4 pieces of tapping screws that fix the motor and unplug the lead wire insert of the motor to take it off As shown in Fig 8 19 Screw...

Страница 30: ...otor to take out the electric box As shown in Fig 8 20 Screws Fig 8 20 8 2 5 Disassembling the reactor box and reactor Screw off the 3 pieces of screws between the reactor box and the base plate to ta...

Страница 31: ...ces Fig 8 23 8 2 7 Disassembling the electromagnetic four way valve Screw off the fixing nut of the four way valve coil and remove the coil Wrap the four way valve with wet sponge and unsolder the 4 s...

Страница 32: ...et cloth to avoid high temperature damage to the valve body Screw off the 2 pieces of bolts that fix the small valve and unsolder the solder joint between the capillary assy and the small valve to tak...

Страница 33: ...33 9 Explosive view and parts and components list 9 Explosive view of indoor unit...

Страница 34: ...34 9 2 Parts and components list of indoor unit The above date is subject to change without further notice...

Страница 35: ...35 The above date is subject to change without further notice...

Страница 36: ...36 9 3 Explosive view of outdoor unit...

Страница 37: ...37 9 4 Parts and components list of outdoor unit The above data is subject to change without further notice Built in Built in...

Страница 38: ...38 The above data is subject to change without further notice Built in Built in...

Страница 39: ...ot water above 45 to prevent fade or deformation 3 Install the front panel Put the props on both ends of the panel into the fulcrum groove and then cover and clasp the panel cover well according to th...

Страница 40: ...step of Cleaning the air filter 10 4 Check before season begins 1 Check if there is blockage in the inlet and outlet vent of indoor and outdoor unit 2 Check if the grounding wire is grounded reliably...

Страница 41: ...use 2 Contact your local GREE special installation and maintenance department prior to installation Malfunction of air conditioner installed by none special department might be difficult to handle in...

Страница 42: ...ed at a location where it is easy to get hold of 11 2 2 Outdoor unit 1 Select a location where the noise and flow of air exhaust will not affect your neighbors 2 Select a location with good ventilatio...

Страница 43: ...pe hole sleeve 11 3 4 Installing the connecting pipe Connect the connecting pipe with the two outlet pipes of indoor unit and tighten the joint nut of the connecting pipe refer to Fig 11 6 Installing...

Страница 44: ...r right side cut the tailing portion for piping left on the base plate of the main unit as shown in Fig 11 4 Cut off tailing 1 when only the power cord is led out Cut off tailings 1 2 when both the co...

Страница 45: ...inal and fix it well Wire distribution must match with that of indoor unit 3 Fix the power connection cord and signal control cable with wire clip Then connect the corresponding connector properly 4 E...

Страница 46: ...ightening the cover check if there is leakage in all connecting points by soup water or detector 10 If possible use vacuum pump to discharge the air in the unit through the one way valve Thin pipe Thi...

Страница 47: ...of wireless remote control Check wireless remote control The power plug is not or poorly connected Check and insert the plug tightly Wrong wiring between indoor and outdoor unit Check the circuit acc...

Страница 48: ...ed Clean the dust accumulated on the surface of the heat exchanger Leakage occurs between high and low pressure inside compressor Replace the compressor Partial blockage of capillary Replace the capil...

Страница 49: ...enough Re wrap and make it tight Abnormal sound and vibration Fan of indoor unit contacts other parts Adjust fan location There is foreign substance in indoor unit Take out the foreign substance Compr...

Отзывы: