18
7.9 HEAT mode operation
●
According to room temperature, set temperature and the change rate of room temperature, microcomputer of the remote
controller will be able to control the output heating capacity of the outdoor compressor.
●
If room temperature is equal to or slightly lower than the set temperature, the compressor will run. If set temperature is 2.5
℃
higher than the room temperature, the compressor will run at its max. capacity. If the difference between room temperature and
set temperature is between 1
℃
and 2.5
℃
, the compressor will stop, the outdoor fan will stop after 30sec and the indoor fan will
run at low speed.
●
If the fan is set at AUTO mode, microcomputer of the remote controller can control the speed of indoor fan via the output power
of outdoor compressor.
●
In this mode, the temperature setting range is 16
℃~
30
℃
.
●
At this time, the LCD appears green.
3. Press the SWING button
and the guide louver starts
to swing automatically and
stops when it is pressed
again.
4. Press the FAN button to
set fan speed.
5. Press the TEMP button
to set the desired
temperature.
1. After power-on, press
the “1/0” button to set the
air conditioner running.
2. Press the MODE button
to select “ ” mode.
Содержание KFR-32GW/NJ1F
Страница 2: ...1 1 Summary and features Models Remark...
Страница 3: ...3 2 Specifications and technical parameters...
Страница 4: ...4...
Страница 7: ...7 4 2 Outline and installation dimension of outdoor unit Unit mm Above 60cm Bolt Nut Spanner...
Страница 33: ...33 9 Explosive view and parts and components list 9 Explosive view of indoor unit...
Страница 34: ...34 9 2 Parts and components list of indoor unit The above date is subject to change without further notice...
Страница 35: ...35 The above date is subject to change without further notice...
Страница 36: ...36 9 3 Explosive view of outdoor unit...
Страница 38: ...38 The above data is subject to change without further notice Built in Built in...