Buzzer
Indicator light
Other
The controller is powered on and detect the signal received, the buzzer will beep.
Auto button
Auto fan speed control
Swing control
Protection method
Anti-freezing protection
If use the remote controller to operate, if the remote controller displays Heat mode, but the unit is cooling
only unit, except receiving unit off signal, the other singal cannot receive.
In Cool or Dehumidify mode, if system anti-freezing protection is detected that the compressor, outdoor fan will stop to run, inner fan,
swing motor will keep the original running status.
Under this mode, inner fan will accord to ambient temperature change automatically select Hi, Mid, Low three speed.
Heat indicator (Yellow): In Auto Heat or Heat mode, the light will turn on, it will blink when defrosting, other mode it is off.
Cool, Dehumidify indicator (Blue):In Cool or Dry mode, auto cool or auto dehumifify mode, it will turn on, other mode it is off,
in Fan mode, the running indicator will turn on.
Running indicator (Red) : When remote control power on, the indicator will blink, when unit is on, it will turn on, while unit off, it is off.
If malfunction happen, it will blink.
When whole unit is running, press this button, the unit is off; when whole unit stop, press this button, the unit will run at auto, auto fan,
and swing mode.
When unit is off, the guide louver will anticlockwise rotate to A position to turn off the air vent.
When power on, the guide louver will anticlockwise rotate to A position to turn off the air vent.
Timer on: If unit is running to set up Timer on, the unit is go on running, if unit is off to set up Timer on, if time out,
the unit will run at the presetting mode.
Timer off: If unit is off to set up Timer off, the unit will stand by, if unit is on to set up Timer off, if time out,
the unit will stop to work.
Timer change:
a. When unit is under Timer, to operate ON/OFF button on remote control to turn on or turn off the unit, or reset the timer can set up the
Timer, the unit will run at the last setting mode.
b. If system is running, to set up the Timer on and Timer off at the same time, the unit will keep running at the current presetting mode,
until the Timer off is time out, the unit will stop to work.
c. If system is stop working, at the same time to set up the Timer on and Timer off, the unit is stopping, until the Timer on is time out, the
unit will start to work.
Hereafter, when the Timer on in every day time out, the unit will run at presettting mode, when Timer off time out, the unit will stop
to work.
d. If the presetting Timer off is the same with Timer on, that the Timer off will be executed
Timer interval setting:
Timer on: At unit off to set up the Timer on function, if time out, the controller will run at the original running status, the timer interval
is 0.5hr, setting range is 0.5-24hrs.
Timer off: At unit on to set up the Timer off function, if time out, the timer interval is 0.5hr, setting range is 0.5-24hrs.
After unit turned on, heating will return to the max. air outlet vent D2 to standby; cooling will firstly rotate to air outlet vent D1 and then
return to air outlet vent D1 and then return to L1 to standby; If it is swinging, the cooling is winging between L1 and D1; the heating is
swinging between the L and D2; Or if it stays, the swing will rotate to the corresponding staying status.