7.1.3
Installation Site of Outdoor Unit
1.Select a site where noise and outflow air emitted by the unit will not annoy neighbors.
2.Select a site where there is sufficient ventilation.
3.Select a site where there is no obstruction blocking the inlet and outlet.
4.The site should be able to withstand the full weight and vibration.
5.Select a dry place, but do not expose the unit to direct sunlight or strong wind.
6.Make sure that the outdoor unit is installed in accordance with the installation instructions, and is convenient for maintena nce
and repair.
7.The height difference between indoor and outdoor units is within 10m, and the length of the connecting tubing does not exce ed
30m.
8.Select a place where it is out of reach of children.
9.Select a place where the unit does not have negative impact on pedestrians or on the city.
7.1.4
Safety Precautions for Electric Appliances
1.A dedicated power supply circuit should be used in accordance with local electrical safety regulations.
2.Don't drag the power cord with excessive force.
3.The unit should be reliably earthed and connected to an exclusive earth device by the professionals.
4.The air switch must have the functions of magnetic tripping and heat tripping to prevent short circuit and overload.
5.The minimum distance between the unit and combustive surface is 1.5m.
6.The appliance shall be installed in accordance with national wiring regulations.
7.An all-pole disconnection switch with a contact separation of at least 3mm in all poles should be connected in fixed wiring.
Note:
Make sure the live wire, neutral wire and earth wire in the family power socket are properly connected.
There should be reliable circuit in the diagram.Inadequate or incorrect electrical connections may cause electric shock or fire.
7.1.5
Earthing Requirements
1.Air conditioner is type I electric appliance. Please ensure that the unit is reliably earthed.
2.The yellow-green wire in air conditioner is the earthing wire which can not be used for other purposes. Improper earthing may
cause electric shock.
3.The earth resistance should accord to the national criterion.
4.The power must have reliable earthing terminal. Please do not connect the earthing wire with the following:
Water pipe
Gas pipe
Contamination pipe
Other place that professional personnel consider is unreliable
5. The model and rated values of fuses should accord with the silk print on fuse cover or related PCB.
Содержание GWH18RC-K3DNA1A
Страница 15: ... QPUVTWEVKQP 8KGYU RQVWUXFWLRQ 9LHZV QGRRU 8QLW ĭ ĭ 0RGHO 8QLW PP ĭ ĭ ...
Страница 16: ... QPUVTWEVKQP 8KGYU 2XWGRRU 8QLW 8QLW PP ...
Страница 40: ... ZRNQFGF 8KGYU CPF 2CTVU KUV SORGHG 9LHZV DQG 3DUWV LVW QGRRU 8QLW 0RGHOV 5 1 5 1 5 1 ...
Страница 42: ... ZRNQFGF 8KGYU CPF 2CTVU KUV 0RGHO 5 1 ...
Страница 50: ... ZRNQFGF 8KGYU CPF 2CTVU KUV 2XWGRRU 8QLW 0RGHO 5 1 2 ...
Страница 52: ... ZRNQFGF 8KGYU CPF 2CTVU KUV 0RGHO 5 1 2 ...
Страница 55: ...6TQWDNGUJQQVKPI 0RGHO 0RGHO ...
Страница 85: ...4GOQXCN 2TQEGFWTG 2 Remove the chassis sub assy and condenser sub assy condenser sub assy chassis sub assy ...