65
Fault Displays
9,000 and 12,000 btuh units
No.
Malfuntiuon
Name
Display Method of Indoor Unit
Display Method of Outdoor Unit
A/C Status
Possible Causes
Dual-8
Code
Display
Indicator Display (during
blinking, ON 0.5s and OFF 0.5s)
Indicator has 3 kinds of display
status and during blinking, ON
0.5ws and OFF 0.5s
Operation
Indicator
Cool
Indicator
Heating
Indicator
Yellow
Indicator
Red
Indicator
Green
Indicator
41
Power
protection
L9
OFF 3S
and blink
20 times
OFF
3S and
blink 9
times
Compressor stop
operation and Outdoor
fan motor will stop 30S
later, 3 minutes later fan
motor and compressor
will restart
To protect the
electronical components
when detect high power
42
Indoor unit
and outdoor
unit doesn't
match
LP
OFF 3S
and blink
19 times
OFF
3S and
blink 16
times
Compressor and
outdoor fan motor can't
work
Indoor unit and outdoor
unit doesn't match
43
Failure start-up LC
OFF
3S and
blink 11
times
During cooling and
drying operation,
compressor will
stop while indoor
fan operate; During
heating operationg, the
complete unit will stop
operation.
Refer to the malfunction
analysis
44
Malfunction of
phase current
detection
circuit for
compressor
U1
OFF
3S and
blink 13
times
During cooling and
drying operation,
compressor will stop
while indoor fan will
operate; During heating
operation, the complete
unit will stop
Replace outdoor control
panel AP1
45
Malfunction
of voltage
dropping for
DC bus-bar
U3
OFF
3S and
blink 20
times
During cooling and
drying operation,
compressor will stop
while indoor fan will
operate; During heating
operation, the complete
unit will stop
Supply voltage is
unstable
46
Malfunction
of complete
units current
detection
U5
OFF
3S and
blink 13
times
During cooling and
drying operation,
compressor will stop
while indoor fan will
operate; During heating
operation, the complete
unit will stop
Theres circuit
malfunction on outdoor
units control panel
AP1. Please replace the
outdoor unit control
panel AP1.