104
Repair or replace pipe
Re-wrap pipe insulation
Drainage pipe blocked or broken
Damaged or insufficient pipe
insulation
Water leakage
General Troubleshooting
Miscellaneous Malfunctions, cont.
Remove object
Adjust support washer of
compressor and tighten screws
Reroute and adjust the tubing
Foreign object in indoor unit
Compressor vibrating or shaking
Outdoor tubing touching
Abnormal sound
and/or shake
Tighten and adjust
Indoor fan loose or hitting sides
Adjust plates, isolate with insulation
Inner plates touching
Adjust louver
Outdoor louver touching outer case
Replace compressor
Abnormal sound inside compressor