5. Electrical Part
5.1 Wiring Diagram
● Indoor Unit
●Instruction
Symbol
Symbol Color
Symbol
Symbol Color
Symbol
Name
WH
White
GN
Green
CAP
Jumper cap
YE
Yellow
BN
Brown
COMP
Compressor
RD
Red
BU
Blue
Grounding wire
YEGN
Yellow/Green
BK
Black
/
/
VT
Violet
OG
Orange
/
/
Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model.
600007062603
BK
COM-OUT
BU
BN
M1
RT1
RT2
PE
DC-MOTOR
T-SENSOR
SWING-LR1
E
TEST-COM
AC-L
SWING-LR2
M3
M2
SWING-UD-PUSH
M5
M6
M4
AP2
DISP1
AP3
COM-PC
AP4
CONNECTION BOARD
AP5
M7
J1
DISPLAY
HUMAN
COM-TRANS
COM-MAIN
N(N1)(N2)
L1
MAGNETIC RING
TEMP.
SENSOR
ROOM TUBE
TEMP.
SENSOR
FAN
MOTOR MOTOR 1
LEFT-RIGHT
MOTOR 2
LEFT-RIGHT
EXTRUSION
MOTOR
SWING
MOTOR
UP-DOWN
AP1:PRINTED CIRCUIT BOARD
CAP
JUMP1
YEGN
YEGN
OUTDOOR UNI
T
USED FOR AFTER-SALES DETECTION
APPLICABLE FOR THE MODEL WITH
AFTER-SALES INSPECTION LINE
DISPLAY BOARD
WIFI DETECTION BOARD
EVAPORATOR
HUMAN BODY INDUCTION METER
HUMAN DRIVE MOTOR
SWING
SWING
LEFT
EXTRUSION
MOTOR
RIGHT