32
Technical Information
Service Manual
● T-OFF button
blinking. " " icon resumes displaying. Cancel T-ON: Unde
the condition that T-ON is started up, press "T-ON " button to
cancel it.
●
simultaneously.
●
●
Before setting T-ON or T-OFF, please adjust the clock time.
Under on and off status, you can set T-OFF or T-ON
After starting up T-ON or T-OFF,set the constant circulating
"T-OFF" button can set the time for timer off. After pressing
this button, " " icon disappears and the word "OFF" on
remote controller blinks. Press "▲" or " ▼ " button to adjust
T-OFF setting. After each pressing "▲" or " ▼ " button, T-OFF
setting will increase or decrease 1min. Hold "▲" or " ▼ "
button, 2s later, the time will change quickly until reaching your
required time. Press "T-OFF" word "OFF" will stop blinking.
" " icon resumes displaying. Cancel T-OFF. Under the
condition that T-OFF is started up, press "T-OFF" button to
cancel it.
Notice:
valid.
After that,air conditioner will be turned on or turned off
according to setting time.ON/OFF button has no effect on
setting.If you don’t need this function, please use remote
controller to cancel it.
● Please put the remote controller near user when this
Press this button to start I FEEL function and " " will be
displayed on the remote controller. After this function is
set, the remote controller will send the detected ambient
temperature to the controller and the unit will automatically
adjust the indoor temperature according to the detected
temperature. Press this button again to cancel I FEEL function
and " " will disappear.
function is set. Do not put the remote contro ller near the
object of high temperature or low temperature in order to
avoid detecting inaccurate amb ient temperature.
When I FEEL function is turned on, the remote controller
should be put within the area where indoor unit can receive
the signal sent by the remote controller.
● Clock time adopts 24-hour mode.
I FEEL
CLOCK
● The interval between two operations can't exceed 5s.
●
Otherwise, remote controller will quit setting status. Operation
for TIMER ON/TIMER OFF is the same.
Press this button, can select Sleep 1 ( 1), Sleep 2 ( 2),
●
Sleep 3 ( 3) and cancel the Sleep, circulate between these,
Press this button to set clock time. " " icon on remote
controller will blink. Press "▲" or " ▼ " button within 5s to set
clock time. Each pressing of "▲" or " ▼ " button, clock time
will increas e or decrease 1 minute.If hold "▲" or " ▼ " button,
2s later, time will change quickly. Release this button when
the time. " " icon stops blinking.
Notice:
Sleep 1 is Sleep mode 1, in Cool modes; sleep status
● Sleep 2 is sleep mode 2, that is air conditioner will run
● Sleep 3-the sleep curve setting under Sleep mode by DIY;
according to the presetting a group of sleep temperature
curve.
after run for one hour, the main unit setting temperature will
increase 1 , two hours, setting temperature increased 2
℃
,
then the unit will run at this setting temperature; In Heat mode:
sleep status after run for one hour, the setting temperature
will decrease 1 , two hours, setting temperature will decrease
2 , then the unit will run at this setting temperature.
●
could be inquired:
Sleep3- the sleep curve setting under Sleep mode by DIY
SLEEP
(1) Under Sleep 3 mode, press “Turbo” button for a long
time, remote controller enters into user individuation sleep
setting status, at this time, the time of remote controller will
display “1hour”, the setting temperature “88” will display the
corresponding temperature of last setting sleep curve and
blink (The first entering will display according to the initial
curve setting value of original factory);
(2) Adjust “+” and “-” button, could change the corresponding
setting temperature, after adjusted, press “Turbo” button for
(3) At this time, 1hour will be automatically increased at the
timer position on the remote control, (that are "2hours" or
"3hours" or "8hours"), the place of setting temperature "88"
will display the corresponding temperature of last setting sleep
curve and blink;
(4) Repeat the above step (2)~(3) operation, until 8 hours
temperature setting finished, sleep,curve setting finished, at
this time, the remote controller will resume the original timer
display; temperature display will resume to original setting
temperature.
The user could accord to sleep curve setting method to inquire
the presetting sleep curve, enter into user individuation sleep
setting status, but do not change the temperature, press
"Turbo" button directly for confirmation. Note: In the above
presetting or enquiry procedure, if continuously within 10s,
there is no button pressed, the sleep curve setting within 10s,
there is no button pressed, the sleep curve setting status
will be automatically quit and resume to display the original
displaying. In the presetting or enquiry procedure, press "ON/
OFF" button, "Mode" button, "Sleep" button, the sleep curve
setting or enquiry status will quit similarly.
Содержание GWH09AGA-K6DNA1A/I
Страница 1: ...Service Manual Change for life GREE ELECTRIC APPLIANCES INC OF ZHUHAI...
Страница 18: ...15 Technical Information Service Manual 841 912 309 373 349 582 646 Unit mm 24K...
Страница 102: ...99 Installation and Maintenance Service Manual 18K...
Страница 103: ...100 Installation and Maintenance Service Manual...
Страница 104: ...101 Installation and Maintenance Service Manual...
Страница 105: ...102 Installation and Maintenance Service Manual Capillary Sub assy...
Страница 107: ...104 Installation and Maintenance Service Manual screws Rear Grill...
Страница 108: ...105 Installation and Maintenance Service Manual...
Страница 109: ...106 Installation and Maintenance Service Manual...
Страница 110: ...107 Installation and Maintenance Service Manual...
Страница 111: ...108 Installation and Maintenance Service Manual...