40
Installation and Maintenance
Service Manual
1. Cooling mode:
Working condition and process of cooling mode:
①
When Tindoor ambient temperature≥Tpreset, unit enters into cooling mode. Indoor fan, outdoor fan and compressor
start operation. Indoor fan operates according to set fan speed.
②
When Tindoor ambient temperature≤Tpreset-2
o
C, compressor stops operation and outdoor fan will stop 30s later.
Indoor fan operates according to set fan speed.
③
When Tpreset-2
o
C<Tindoor ambient temperature<Tpreset, unit operates according to the previous status.
Under cooling mode, 4-way valve is not energized. Temperature setting range is 16~30
o
C. If compressor stops because of
malfunction in cooling mode, indoor fan and swing motor will work according to the original status.
2. Drying mode
(1) Working condition and process of drying mode
①
When Tindoor ambient temperature>Tpreset, unit will be in drying mode. Outdoor fan and compressor start operation
while indoor fan will operate at low fan speed.
②
When Tpreset-2
o
C≤Tindoor ambient temperature≤Tpreset, unit operates according to the previous status.
③
When Tindoor ambient temperature<Tpreset-2
o
C, compressor stops operation and outdoor fan will stop 30s later.
(2) Under drying mode, 4-way valve is not energized. Temperature setting range is 16~30
o
C.
(3) Protection function: same as in cooling mode.
3. Fan mode
(1) Under this mode, indoor fan can select different fan speed (except Turbo) or auto fan speed. Compressor, outdoor fan
and 4-way valve all stop operation.
(2) In fan mode, temperature setting range is 16~30
o
C.
4. Heating mode
Working condition and process of heating mode:
①
When Tpreset-(Tindoor ambient temperature-Tcompensation)≥1
o
C, unit enters into heating mode. Compressor,
outdoor fan and 4-way valve start operation.
②
When -2
o
C<Tpreset-(Tindoor ambient temperature-Tcompensation)<1
o
C, unit operates according to the previous
status.
③
When Tpreset-(Tindoor ambient temperature-Tcompensation)≤-2
o
C, compressor stops operation and outdoor fan
will stop 30s later. Indoor fan will be in residual-heat blowing status.
④
When unit is turned off under heating mode or changed to other modes from heating mode, 4-way valve will be
power-off 2min after compressor stops working (compressor is in operation status under heating mode).
⑤
When Toutdoor ambient temperature>30
o
C, compressor stops operation immediately. Outdoor fan will stop 30s later.
⑥
Under the condition that compressor is turned on, when unit is changed to heating mode from cooling or drying mode,
4-way valve will be energized in 2~3mins delay.
Note: Tcompensation is determined by IDU and ODU. If IDU controls the compensation temperature, then Tcompensation is
determined according to the value sent by IDU to ODU; If IDU does not control the compensation temperature, then
Tcompensation will default to 3
o
C by the ODU.
5. Freon recovery mode
After the Freon recovery signal from IDU is received, cooling at rated frequency will be forcibly turned on to recover Freon.
Indoor unit will display Fo. If any signal from remote controller is received, unit will exit from Freon recovery mode and
indoor unit stops displaying Fo.
6. Compulsory defrosting
If unit is turned on under heating mode and set temperature is 16
o
C (by remote controller), press “+, -, +, -, +, -” within
5s, unit will enter into compulsory defrosting mode and send the signal to ODU. When the compulsory defrosting signal from
ODU is received, IDU will exit from the compulsory defrosting mode and stop sending the signal to ODU.
After ODU receives the compulsory defrosting code, it will start compulsory defrosting. Defrosting frequency and opening
angle will be the same as in normal defrosting mode. When compulsory defrosting is finished, the complete unit resumes
original status.
●
Outdoor Unit
Содержание GWH09AGA-K6DNA1A/I
Страница 1: ...Service Manual Change for life GREE ELECTRIC APPLIANCES INC OF ZHUHAI...
Страница 18: ...15 Technical Information Service Manual 841 912 309 373 349 582 646 Unit mm 24K...
Страница 102: ...99 Installation and Maintenance Service Manual 18K...
Страница 103: ...100 Installation and Maintenance Service Manual...
Страница 104: ...101 Installation and Maintenance Service Manual...
Страница 105: ...102 Installation and Maintenance Service Manual Capillary Sub assy...
Страница 107: ...104 Installation and Maintenance Service Manual screws Rear Grill...
Страница 108: ...105 Installation and Maintenance Service Manual...
Страница 109: ...106 Installation and Maintenance Service Manual...
Страница 110: ...107 Installation and Maintenance Service Manual...
Страница 111: ...108 Installation and Maintenance Service Manual...