35
Technical Information
Service Manual
(4) When setting the initial temperature 30
℃
, under this temperature setting, after 7hours, the temperature will be decreased 1
℃
, after
that the unit will keep onrunning under this temperature;
In Heat mode:
(1) Under the initial presetting temperature 16
℃
, it will run under this setting temperature all along.
(2) Under the initial presetting temperature17
℃
-20
℃
, after Sleep function started up, the temperature will decrease 1
℃
in every hour,
after 1
℃
decreased, thistemperature will be maintained.
(3) Under the initial presetting temperature 21
℃
-27
℃
, after Sleep function started up, the temperature will decrease 1
℃
in every hour,
after 2
℃
decreased, thistemperature will be maintained.
(4) Under the initial presetting temperature 28
℃
-30
℃
, after Sleep function started up, the temperature will decrease 1
℃
in every hour,
after 3
℃
decreased, thistemperature will be maintained.
Sleep 3 - the sleep curve setting under Sleep mode by DIY:
(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote controller enters into user individuation sleep setting status, at this
time, the time of remotecontroller will display "1hour", the setting temperature "88" will display the corr-esponding temperature of last setting
sleep curve and blink (The first enteringwill display according to the initial curve setting value of original factory);
2) Adjust "+" and "-" button, could change the corresponding setting temperature,after adjusted, press "Trubo" button for confirmation;
(3) At this time, 1hour will be automatically increased at the timer postion on the remote controller, (that are "2hours" or "3hours" or "8hours"),
the place of setting temperature "88" will display the corresponding temperature of last settingsleep curve and blink;
(4) Repeat the above step (2)~(3) operation, until 8hours temperature setting finished,sleep curve setting finished, at this time, the remote
controller will resume theoriginal timer display; temperature display will resume to original setting temperature.
Sleep3 - the sleep curve setting under Sleep mode by DIY could be inquired:The user could accord to sleep curve setting method to inquire
the presetting sleepcurve, enter into user individuation sleep setting status, but do not change the temperature, press "Turbo" button directly
for confirmation.
Note: In the above presetting or enquiry procedure, if continuously within10s, thereis no button pressed, the sleep curve setting status will
be automatically quitand resume to display the original displaying. In the presetting or enquiry pr-ocedure, press "ON/OFF" button, "Mode"
button, "Timer" button or "Sleep" button, the sleep curve setting or enquiry status will quit similarly.
Introduction for special function
About AUTO RUN
When AUTO RUN mode is selected, the unit will be in accordance with the room temp. automatically to select the suitable running method
and to make ambient comfortable.
About turbo function
If start this function, the unit will run at super-high fan speed to cool or heat quickly sothat the ambient temp. approachs the preset temp.
as soon as possible.
About lock
Press + and - buttons simultaneously to lock or unlock the keyboard. If the remote co-ntroller is locked , the icon will be displayed on it,
in which case, press any button, the mark will flicker for three times. If the keyboard is unlocked, the mark will disappear.
About swing up and down
1. Press swing up and down button continuously more than 2s, the m ain unit will swingbackand forth from up to down , and then loosen
the button, the unit will stop swingand present position of guide louver will be kept immediately.
2. Under swing up and down mode, when the status is switched from off to , if pressthis button again 2s later, status will switch to off
status directly; If press this buttonagain within 2s, the change of swing status will also depend on the circulation seque-nce stated above.
About swing left and right
1. Press swing left and right button continuously more than 2s, the main unit will swingback and forth from left to right, and then loosen the
button, the unit will stop swingand present position of guide louver will be kept immediately.2. Under swing left and right mode, when the
status is switched from off to , if pressthis button again 2s later, status will switch to off status directly; if press this button again within
2s, the change of swing status will also depend on the circulation sequ-ence stated above.
About switch between Fahrenheit and Centigrade
Under status of unit off, press MODE and - buttons simultaneously to switch
℃
and
℉
.
Combination of "TEMP" and "CLOCK" buttons: About Energy - saving Function
Press “TEMP” and “CLOCK” simultaneously in COOL mode to start energy-saving fun-ction. Nixie tube on the remote controller displays
“SE”. Repeat the operation to quit the function.
Combination of "TEMP" and "CLOCK" buttons: About 8
℃
Heating Function
Press “TEMP” and “CLOCK” simultaneously in HEAT mode to start 8
℃
Heating Function Nixie tube on the remote controller displays “ ” and
a selected temperature of “8
℃
”. (46
℉
if Fahrenheit is adopted). Repeat the operation to quit the function.
About Quiet function
When quiet function is selected:
1. Under cooling mode: indoor fan operates at notch 4 speed. 10 minutes later or whenindoor ambient temperature≤28
℃
, indoor fan will
operate at notch 2 speed or quietmode according to the comparison between indoor ambinet temperature and set tem-perature.
2. Under heating mode: indoor fan operates at notch 3 speed or quiet mode accordingto the comparison between indoor ambient
temperature and set temperature.
3. Under dry, fan mode: indoor fan operates at quiet mode.
4. Under auto mode: the indoor fan operates at the auto quiet mode according to actual cooling, heating or fan mode.
About Sleep function
Under the Fan
、
Dry and Auto mode, the Sleep function cannot be set up, Select and enter into any kind of Sleep mode, the Quiet function
will be attached and stared, different Quiet status could be optional and turned off.