Φ
6 - 6.35(1/4")
Φ
9.52(3/8")
Φ
12-12.7(1/2")
Φ
15.8-16(5/8")
1.3
0.7
1.6
1.0
1.8
1.0
2.4
2.2
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
the distance of indoor unit and
outdoor unit.
●
Cut the required pipe with pipe cutte
r
.
pipe
pipe cutter
leaning
uneven
burr
B: Remove the burrs
●
Remove the burrs with shaper and
prevent the burrs from getting into
the pipe.
downwards
pipe
shaper
C: Put on suitable insulating pipe
D: Put on the union nut
●
Remove the union nut on the indoor
connection pipe and outdoor valve;
install the union nut on the pipe.
union pip
e
pipe
E: Expand the port
●
Expand the port with expande
r
.
Note:
●
"A" is different according to the
diamete
r
, please refer to the sheet
below:
expander
hard
mold
pipe
F: Inspection
●
Check the quality of expanding port.
If there is any blemish, expand the
port again according to the steps
above.
the length is equal
improper expanding
leaning
damaged
surface
crack
uneven
thickness
smooth surface
Outer diameter
(mm)
A(mm)
Max
Min