1.

2.

Select a position where the condensing water can be easily drained out, and the place

is easily connected for outdoor unit.

4.

Can select the place where is strong enough to withstand the full weight and vibration of

the unit. And will not increase the noise.

5.

6.

7.
8.

Make sure that the indoor unit installation should accord with installation dimension 

diagram requirements. 

3.

Select a location where the children can not reach.

1.

The unit installation work must be done by qualified personnel according to the local

rules and this manual.

2.

Before installation, please contact with local authorized maintenance center, if unit is

not installed by the authorized maintenance center, the malfunction may not solved,

due to discommodious contacts.

3.

W

4.

the appliance must be  positioned so that the plug is accessible

hen removing the unit to the other place, please firstly contact with the authorized

Maintenance Center in the local area.

Notices for installation

Important Notices

Basic Requirements F

or Installation Position

Install in the following place may cause malfunction. If it is unavoidable contact with 

service center please:

Place where strong heat sources, vapors, flammable gas or volatile object are emitted.

Place where high-frequency waves are generated by radio equipment, welders and 

medical equipment.

Place where a lot of salinities such as coast exists.

Place where the oil (machine oil) is contained in the air.

Place where a sulfured gas such as the hot spring zones is generated.

Other place with special circumstance.

Indoor Unit Installation Position Selection

The air inlet and outlet vent should be far from the obstruction, make sure that the air

can be blown through the whole room.

Be sure to leave enough space to allow access for routine maintenance. The height of the

installed location should be 250cm or more from the floor.

Select a place about 1m or more away from TVset or any other electric appliances.

Select a place where the filter can be easily taken out.

.

Do not use the unit in the immediate surroundings of a laundry a bath a shower or a

swimming pool.

9

17

1.

Select a location from which noise and outflow air emitted by unit will not inconvenience

     neighbors, animals, plants.

2.

Select a location where there should be sufficient ventilation.

3.

Select a location where there should be no obstructions cover the inlet and outlet vent.

4.

The location should be able to withstand the full weight and vibration of the outdoor unit

     and permit safe installation.

5.

Select a dry place, but do not expose under the direct sunlight or strong wind.

6.

7.

8.

9.

Outdoor Unit Installation Position Selection

Make sure that the outdoor unit installation dimension should accord with installation 

dimension diagram, convenient for maintenance, repair.

The height difference of connecting the tubing within 5m, the length of connecting the

tubing within 10m.

Select a place where it is out of reach for the children.

Select a place where will not block the passage and do not influence the city appearance.

Содержание GWC09KF-D3DNA7A

Страница 1: ...e Split Air Conditioner Owner s Manual Residential Air Conditioners Thank you for choosing Residential manual carefully before operation and retain it for future reference Air Conditioners please read...

Страница 2: ...9KF K3DNA9A GWH12KF K3DNA9A GWC09KF K3DNA5D GWC12KF K3DNA5D GWH09KF K3DNA5B GWH12KF K3DNA5B GWH09KF K3DNB1A GWH12KF K3DNB1A GWH12KF K3DNA6B GWC12KF K3DNA7A GWC09KF K3DNA7A GWC12KF D3DNA7A GWC09KF D3DN...

Страница 3: ...iance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruct...

Страница 4: ...n for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block the air intake or outlet vents of both the outdoor and indoor units It can decrease the...

Страница 5: ...ver of left right direction Louver of upward downward direction Don t insert your hands or stick into the air intake or outlet vents Otherwise it will cause accident Don t blow the wind to animals and...

Страница 6: ...ty will increase or decrease by outdoor ambient temperature If the unit is running in COOL mode and in low temperature there will be frost formed on the heat exchanger when indoor heat exchanger tempe...

Страница 7: ...outdoor temperature for cooling unit is 21 43 for cooling and heating unit is 5 43 Working temperature range Maximum cooling Minimum cooling Maximum heating Minimum heating Indoor sideDB WB o C Outdo...

Страница 8: ...door unit Outdoor unit Wireless remote control Power cable Remote control Front panel Filter Guide louver Wall pipe Bind tape Drainage pipe Receive window Heat Cool Run Dry SET TEMP ON OFF 5 Air out A...

Страница 9: ...the button continuously and setting temp range is by pressing Operation of wireless remote control Swing up and down button below Press this button the running mode will change as Mode button MODE FAN...

Страница 10: ...p flickering If the time of that no press timer button under flickering status is above 5s the timer setting will quit If the timer has been set press this button once again to quit it press this key...

Страница 11: ...ed with the stop of the unit There is no SLEEP function under AUTO is the icon for sleep function SLEEP Sleep button At COOL DRY mode the SLEEP mode runs after 1hour the setting temp will be increased...

Страница 12: ...button set the sleep mode 2 Press TIMER button then press button to set the 3 Press light button to control displayer light on or off 4 Press X FAN button to set X FAN function on or off 5 Press turbo...

Страница 13: ...temp automatically to select the suitable running method and to make ambient comfortable About turbo function If start this function the unit will run at super high fan speed to cool or heat quickly s...

Страница 14: ...to the light at sleeping Get the displayer indicator light on When setting the light function the mark will pressing this button In which case the diss player indicator light will be on if the AC rec...

Страница 15: ...d hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filte...

Страница 16: ...act the dealer Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies C...

Страница 17: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is run...

Страница 18: ...in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leaka...

Страница 19: ...mething into unit There is an abnormal heat in power supply cord and power plug Stop running and pull out of the plug In HEAT mode when the temperature of indoor heat exchanger is very low that will s...

Страница 20: ...ntained in the air Place where a sulfured gas such as the hot spring zones is generated Other place with special circumstance Indoor Unit Installation Position Selection The air inlet and outlet vent...

Страница 21: ...amination pipe Other places that professional personnel consider them unreliable 5 The appliance shall be installed in accordance with national wiring regulations An all pole disconnection switch havi...

Страница 22: ...sions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures 19 Space to the wall Above Above Space to the obstruction Air...

Страница 23: ...ole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole Install the water drainage pipe 1 For well draining the drain hose should be place...

Страница 24: ...ff the tailings 1 and tailings 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As...

Страница 25: ...cord anchorage for cooling and heating unit use the cord anchorage to fix the power connection cable and the signal control wire Ensure wire has been fixed well Install the handle 5 1 0 10 pa 76cmHg...

Страница 26: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely...

Страница 27: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and rein...

Страница 28: ...ts Correct Incorrect Note It is required to equip snow guard and a higher foundation base to prevent snow from covering air inlet and outlet Snow guard Snow guard Install in windward side seasonal win...

Страница 29: ...Add West Jinji Rd Qianshan Zhuhai Guangdong China 519070 Tel 86 756 8522218 Fax 86 756 8669426 E mail gree gree com cn www gree com GREE ELECTRIC APPLIANCES INC OF ZHUHAI 66162760...