88
4
1
2
3
Removal Procedure
Solder off the welding spot of
capillary and valve and outlet
pipe of condenser.
Remove the 2 screws fixing the
gas valve. Solder off the weld
spot connecting gas valve and
air return pipe and remove the
gas valve.
(Note: it is necessary to warp
the gas valve when soldering
off the welding spot.)
Remove the 2 screws fixing
liquid valve. Solder off the
welding spot connecting liquid
valve and remove the liquid valve.
Solder off the pipe connected
with the compressor.
Remove compressor
Remove the 3 footing
screws of the compressor
and remove the compressor.
Содержание GWC09KF-D3DNA5A
Страница 25: ...22 Schematic Diagram wire live wire communication wire ground wire Display board infrared receiver neutral...
Страница 26: ...23 TOP VIEW BOTTOM VIEW Schematic Diagram...
Страница 27: ...24 FRONT VIEW BOTTOM VIEW Schematic Diagram...
Страница 28: ...25 TOP VIEW BOTTOM VIEW Schematic Diagram...
Страница 71: ...83 Removal Procedure 13 Remove Motor Sub Assy 14 Remove Fan Motor Remove Motor Sub Assy 1...