9
Unit
GWC12KF-D3DNA5A
GWH12KF-D3DNA5A
CB14600030
CB14600040
Rated Voltage
V
~
208~230
208~230
Rated Frequency
Hz
60
60
Phases
1
1
outdoor
outdoor
Btu/h
12000(3300
~
12500)
12000(3300
~
12500)
Btu/h
-
12000(3400
~
12500)
W
1160(260
~
1340)
1160(260
~
1340)
W
-
950(260
~
1000)
A
5.40
5.40
A
-
4.35
W
1340
1340
A
5.94
5.94
m
3
/h
580
580
L/h
1.4
1.4
Btu/w.h
3.03
3.03
Btu/w.h
-
3.70
Btu/w.h
16.00
16.00
Btu/w.h
-
8.50
m
2
16-24
16-24
Model of indoor unit
GWC12KF-D3DNA5A/I
GWH12KF-D3DNA5A/I
Fan Type
Cross-flow
Cross-flow
Diameter Length(DXL)
mm
φ
92X595.5
φ
92X595.5
Fan Motor Cooling Speed
(SH/H/M/L)
r/min
1350/1150/950/750
1350/1150/950/750
Fan Motor Heating Speed
(SH/H/M/L)
r/min
-
1350/1200/100/850
Output of Fan Motor
W
15
15
Fan Motor RLA
A
0.19
0.19
Fan Motor Capacitor
μ
F
1.2
1.2
Input of Heater
W
-
-
Evaporator Form
Aluminum Fin-copper Tube
Aluminum Fin-copper Tube
Pipe Diameter
mm
φ
7
φ
7
Row-fin Gap
mm
2-1.4
2-1.4
Coil Length (LXDXW)
mm
610X24X294
610X24X294
Swing Motor Model
MP24BA
MP24BA
Output of Swing Motor
W
1.5
1.5
Fuse
A
PCB3.15A
PCB3.15A
Sound Pressure Level
(SH/H/M/L)
dB (A)
44/39/33/28
44/39/33/28
Sound Power Level (SH/H/M/L)
dB (A)
54/49/43/38
54/49/43/38
Dimension (WXHXD)
mm
770X283X201
770X283X201
Dimension of Carton Box
(L/W/H)
mm
844X261X342
844X261X342
Dimension of Package (L/W/H)
mm
847X264X357
847X264X357
Net Weight
kg
9
9
Gross Weight
kg
12
12
Indoor
Unit
Value
COP
SEER
HSPF
Application Area
Rated Current
Air Flow Volume(SH/H/M/L)
Dehumidifying Volume
EER
Heating Power Input (Min
~
Max)
Cooling Power Current
Heating Power Current
Rated Input
Power Supply Mode
Cooling Capacity (Min
~
Max)
Heating Capacity (Min
~
Max)
Cooling Power Input (Min
~
Max)
Parameter
Model
Product Code
Power
Supply
Specifications
Содержание GWC09KF-D3DNA5A
Страница 25: ...22 Schematic Diagram wire live wire communication wire ground wire Display board infrared receiver neutral...
Страница 26: ...23 TOP VIEW BOTTOM VIEW Schematic Diagram...
Страница 27: ...24 FRONT VIEW BOTTOM VIEW Schematic Diagram...
Страница 28: ...25 TOP VIEW BOTTOM VIEW Schematic Diagram...
Страница 71: ...83 Removal Procedure 13 Remove Motor Sub Assy 14 Remove Fan Motor Remove Motor Sub Assy 1...