The use of “Oxygen Free and Dry Nitrogen” (OFDN)
Flushing the system and providing a “Holding Charge” of
OFDN to the system:
After HC refrigerant removal (venting and recovery by vacuum pump) from the
system, the empty refrigerant circuit should be flushed with OFDN in order to
assure that there is no remaining HC in the system but also to blow-out other
possible contaminants including humidity. In case of no further actions to the
system e.g. disassembly of indoor and outdoor unit for transport to the compa-
nies repair shop or an on-site specific components replacement at a later date,
an OFDN holding charge should be supplied to the refrigerant circuit. This is in
general to avoid that air or humidity will be introduced into the system and cause
contamination.
Provide a filled Nitrogen Cylinder (containing OFDN gas) equipped with reliable
pressure regulator and Nitrogen transfer hose (N), having a
¼
” SAE female
adapter and with Schrader valve core depressor. Secure the cylinder!
The warning sign is still placed in the work-area because we are now handling a
pressurised (about 250 bar) cylinder and OFDN gas is intentionally blown off
from the system to the ambient area!
L
N
Never switch
ON the AC
system if
charged with
OFDN!
Содержание GWC09AA
Страница 1: ...GREE Service Manual GWC09AA K5NNA6A Page 1 Models GWC09AA K5NNA6A Installation and Service Manual...
Страница 20: ...GREE Service Manual GWC09AA K5NNA6A Page 20 Outdoor Unit...
Страница 27: ...GREE Service Manual GWC09AA K5NNA6A Page 27 Functional description and controls The remote control...
Страница 28: ...GREE Service Manual GWC09AA K5NNA6A Page 28...
Страница 29: ...GREE Service Manual GWC09AA K5NNA6A Page 29 Unit Functions...
Страница 58: ...GREE Service Manual GWC09AA K5NNA6A Page 58 Installation Dimension Diagram...
Страница 112: ...GREE Service Manual GWC09AA K5NNA6A Page 112 Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Unit...
Страница 114: ...GREE Service Manual GWC09AA K5NNA6A Page 114 Resistance Table of Compressor Discharge Temperature Sen sor Outdoor Unit...
Страница 117: ...GREE Service Manual GWC09AA K5NNA6A Page 117...
Страница 118: ...GREE Service Manual GWC09AA K5NNA6A Page 118...
Страница 119: ...GREE Service Manual GWC09AA K5NNA6A Page 119...
Страница 120: ...GREE Service Manual GWC09AA K5NNA6A Page 120...
Страница 122: ...GREE Service Manual GWC09AA K5NNA6A Page 122...
Страница 123: ...GREE Service Manual GWC09AA K5NNA6A Page 123...
Страница 124: ...GREE Service Manual GWC09AA K5NNA6A Page 124...
Страница 125: ...GREE Service Manual GWC09AA K5NNA6A Page 125...
Страница 126: ...GREE Service Manual GWC09AA K5NNA6A Page 126 Exploded View of the GREE HC R 290 AC Split System Indoor Unit...
Страница 127: ...GREE Service Manual GWC09AA K5NNA6A Page 127 Part List Indoor Unit...
Страница 128: ...GREE Service Manual GWC09AA K5NNA6A Page 128 Exploded View of the GREE HC R 290 AC Split System Outdoor Unit...
Страница 129: ...GREE Service Manual GWC09AA K5NNA6A Page 129 Part List Outdoor Unit...
Страница 130: ...GREE Service Manual GWC09AA K5NNA6A Page 130 Recommended Equipment and Tools for Hydrocarbon Refrigerants Servicing...
Страница 131: ...GREE Service Manual GWC09AA K5NNA6A Page 131...
Страница 132: ...GREE Service Manual GWC09AA K5NNA6A Page 132...
Страница 133: ...GREE Service Manual GWC09AA K5NNA6A Page 133...
Страница 134: ...GREE Service Manual GWC09AA K5NNA6A Page 134...
Страница 135: ...GREE Service Manual GWC09AA K5NNA6A Page 135...
Страница 136: ...GREE Service Manual GWC09AA K5NNA6A Page 136...