GREE Service Manual GWC09AA / K5NNA6A
Page 102
Start Up Data Sheet for GREE Split Air-Conditioner—Service and Repair
Installation Company
Address
Telephone & Fax
Technician Name
Registration No.
Client / Company
Contact Person
Installation / Appliance DATA
Model and No.
Date of Installation / Repair
Comments / Repair
Operating Data –
Cooling Mode
Refrigerant Type
R-290
Flammable Refrigerant
Refrigerant Name
Propane
Refrigerant charge in kg
0.20
Suction Pressure P1
Suction Temp. P1
Air Temp. entering condenser T3
Air Temp. leaving condenser T4
Air Temp. entering evaporator T1
Air Temp. leaving evaporator T2
Performance Test: With appliance commissioning please operate the Split- Air con-
ditioner with HIGH indoor fan speed in mode COOLING for a minimum of 15 Minutes.
Measure air inlet (T1) and air outlet (T2) temperature at the indoor unit.
The tempera-
ture difference should be at least 8 K.
Electrical Data
Power Supply (Voltage)
Overall Ampere Reading
Current draw Compressor
Other executions for system commissioning! Tick box for completion
Only use correct and reliable tools / equipment for system commissioning!
Functional AC system check including performance test!
Check the Ac system for refrigerant leakage!
Check that electrical connections are tight!
Check that condensate drain is tight and with down-grade!
Check insulation of refrigerant transfer tubes and quick-coupler!
Check free run of condenser and evaporator fans!
Check system operation (indoor/outdoor) on abnormal operational noise!
Clean system components including air filter (if indicated)
Check display of the remote controller!
Execute briefing of the AC system user!
Company signature and date:
Client signature and date:
Содержание GWC09AA
Страница 1: ...GREE Service Manual GWC09AA K5NNA6A Page 1 Models GWC09AA K5NNA6A Installation and Service Manual...
Страница 20: ...GREE Service Manual GWC09AA K5NNA6A Page 20 Outdoor Unit...
Страница 27: ...GREE Service Manual GWC09AA K5NNA6A Page 27 Functional description and controls The remote control...
Страница 28: ...GREE Service Manual GWC09AA K5NNA6A Page 28...
Страница 29: ...GREE Service Manual GWC09AA K5NNA6A Page 29 Unit Functions...
Страница 58: ...GREE Service Manual GWC09AA K5NNA6A Page 58 Installation Dimension Diagram...
Страница 112: ...GREE Service Manual GWC09AA K5NNA6A Page 112 Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Unit...
Страница 114: ...GREE Service Manual GWC09AA K5NNA6A Page 114 Resistance Table of Compressor Discharge Temperature Sen sor Outdoor Unit...
Страница 117: ...GREE Service Manual GWC09AA K5NNA6A Page 117...
Страница 118: ...GREE Service Manual GWC09AA K5NNA6A Page 118...
Страница 119: ...GREE Service Manual GWC09AA K5NNA6A Page 119...
Страница 120: ...GREE Service Manual GWC09AA K5NNA6A Page 120...
Страница 122: ...GREE Service Manual GWC09AA K5NNA6A Page 122...
Страница 123: ...GREE Service Manual GWC09AA K5NNA6A Page 123...
Страница 124: ...GREE Service Manual GWC09AA K5NNA6A Page 124...
Страница 125: ...GREE Service Manual GWC09AA K5NNA6A Page 125...
Страница 126: ...GREE Service Manual GWC09AA K5NNA6A Page 126 Exploded View of the GREE HC R 290 AC Split System Indoor Unit...
Страница 127: ...GREE Service Manual GWC09AA K5NNA6A Page 127 Part List Indoor Unit...
Страница 128: ...GREE Service Manual GWC09AA K5NNA6A Page 128 Exploded View of the GREE HC R 290 AC Split System Outdoor Unit...
Страница 129: ...GREE Service Manual GWC09AA K5NNA6A Page 129 Part List Outdoor Unit...
Страница 130: ...GREE Service Manual GWC09AA K5NNA6A Page 130 Recommended Equipment and Tools for Hydrocarbon Refrigerants Servicing...
Страница 131: ...GREE Service Manual GWC09AA K5NNA6A Page 131...
Страница 132: ...GREE Service Manual GWC09AA K5NNA6A Page 132...
Страница 133: ...GREE Service Manual GWC09AA K5NNA6A Page 133...
Страница 134: ...GREE Service Manual GWC09AA K5NNA6A Page 134...
Страница 135: ...GREE Service Manual GWC09AA K5NNA6A Page 135...
Страница 136: ...GREE Service Manual GWC09AA K5NNA6A Page 136...