GREE Service Manual GWC09AA / K5NNA6A
Page 79
Refrigerant Venting—Part 2
After determining that there is obviously no flow of refrigerant venting from the
outdoor unit, a proportionally high residual amount of HC refrigerant is absorbed
within the compressor lubricant and left in the system. To empty the system
from residual HC refrigerant as much as possible, a vacuum pump should be
connected to the system. Disconnect the recovery cylinder (oil-separator) from
the system and install the vent-line to the exhaust port of the vacuum pump. The
free end of the vent-line remains on the stand as described on the previous
page of this section. Lowering the pressure in the system, the residual refriger-
ant absorbed within the lubricant starts evaporating and gets transferred with
the vacuum pump and vent-line to the ambient.
A flammable gas warning sign must be positioned close to the hose discharge
port to indicate that there is an occurrence of flammable gas during venting ac-
tivity.
D
C
B
A
Vent Line
Stand
E
L
K
F
Содержание GWC09AA
Страница 1: ...GREE Service Manual GWC09AA K5NNA6A Page 1 Models GWC09AA K5NNA6A Installation and Service Manual...
Страница 20: ...GREE Service Manual GWC09AA K5NNA6A Page 20 Outdoor Unit...
Страница 27: ...GREE Service Manual GWC09AA K5NNA6A Page 27 Functional description and controls The remote control...
Страница 28: ...GREE Service Manual GWC09AA K5NNA6A Page 28...
Страница 29: ...GREE Service Manual GWC09AA K5NNA6A Page 29 Unit Functions...
Страница 58: ...GREE Service Manual GWC09AA K5NNA6A Page 58 Installation Dimension Diagram...
Страница 112: ...GREE Service Manual GWC09AA K5NNA6A Page 112 Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Unit...
Страница 114: ...GREE Service Manual GWC09AA K5NNA6A Page 114 Resistance Table of Compressor Discharge Temperature Sen sor Outdoor Unit...
Страница 117: ...GREE Service Manual GWC09AA K5NNA6A Page 117...
Страница 118: ...GREE Service Manual GWC09AA K5NNA6A Page 118...
Страница 119: ...GREE Service Manual GWC09AA K5NNA6A Page 119...
Страница 120: ...GREE Service Manual GWC09AA K5NNA6A Page 120...
Страница 122: ...GREE Service Manual GWC09AA K5NNA6A Page 122...
Страница 123: ...GREE Service Manual GWC09AA K5NNA6A Page 123...
Страница 124: ...GREE Service Manual GWC09AA K5NNA6A Page 124...
Страница 125: ...GREE Service Manual GWC09AA K5NNA6A Page 125...
Страница 126: ...GREE Service Manual GWC09AA K5NNA6A Page 126 Exploded View of the GREE HC R 290 AC Split System Indoor Unit...
Страница 127: ...GREE Service Manual GWC09AA K5NNA6A Page 127 Part List Indoor Unit...
Страница 128: ...GREE Service Manual GWC09AA K5NNA6A Page 128 Exploded View of the GREE HC R 290 AC Split System Outdoor Unit...
Страница 129: ...GREE Service Manual GWC09AA K5NNA6A Page 129 Part List Outdoor Unit...
Страница 130: ...GREE Service Manual GWC09AA K5NNA6A Page 130 Recommended Equipment and Tools for Hydrocarbon Refrigerants Servicing...
Страница 131: ...GREE Service Manual GWC09AA K5NNA6A Page 131...
Страница 132: ...GREE Service Manual GWC09AA K5NNA6A Page 132...
Страница 133: ...GREE Service Manual GWC09AA K5NNA6A Page 133...
Страница 134: ...GREE Service Manual GWC09AA K5NNA6A Page 134...
Страница 135: ...GREE Service Manual GWC09AA K5NNA6A Page 135...
Страница 136: ...GREE Service Manual GWC09AA K5NNA6A Page 136...