Service Manual
8
Technical Information
4. Refrigerant System Diagram
Connection pipe specification:
Liquid : 1/4" (6 mm)
Gas : 5/8" (16mm)
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
COOLING
HEATING
Accumlator
4-Way valve
COOLING
Discharge
Suction
Discharge
Suction
Heat
exchanger
(evaporator)
Heat
exchanger
(evaporator)
Heat
exchanger
(condenser)
Valve
Valve
Valve
Valve
Liquid pipe
side
Gas pipe
side
Liquid pipe
side
Gas pipe
side
Compressor
Strainer
Strainer
Electronic
expansion
Strainer
Capillary