3.1.2 Selection of Installation Location
WARNING
!
(1) If the outdoor unit will be exposed in strong wind, it must be securely located,
otherwise it may fall down.
(2) Install the air conditioner at a place where the inclination is less than 5°.
(3) Do not install the unit at a place with direct sunlight.
(4) Do not install the unit at a place with leakage of inflammable gas.
Selection of Installation Location for Indoor Unit (Select a location
pursuant to the following condition).
(1) Air inlet and outlet of the indoor unit should be away from obstacles to
make sure the unit’s air flow can reach the entire room. Do not install the
unit in a kitchen or a laundry.
(2) Install the unit in a room without naked flame, fire source or the risk of
getting the refrigerant on fire.
(3) Select a location that can withstand 4 times the unit weight without
increasing operating noise and vibration.
(4) The installation location must be level.
(5) The indoor piping length and wiring length should be within the allowable
range.
(6) Select a place that can easily drain condensate and connect to the drain
system of the air conditioner.
(7) If hoisting screw bolts are to be used, check whether the installation
location is safe enough. If not safe, reinforce the location before
installation.
(8) Indoor unit, power cord, connecting wires and communication cords
should be at least 1m from television and radio. This is to prevent image
interference or noise (Even at a distance of 1m, a very strong electric
wave may still generate noise).