5HPRYDO3URFHGXUH
Steps
Procedure
screw
screw
nut
nut
16. Remove centrifugal blade
centrifugal blade
centrifugal blade
Remove the fixing nut and washer to
remove the centrifugal blade.
17. Remove volute 2(upper)
foam(connected to water tray)
volute 2(upper)
Remove the 3 fixing screws to remove
the volute 2(upper) and then remove
the foam(connected to water tray).
18. Remove flow-guide loop
flow-guide loop
Turn the duct assy upside down and
then remove the 3 fixing screws to
remove the flow-guide loop.
19. Remove centrifugal blade
Remove the fixing nut and washer to