32
Maintenance
Service Manual
●Correct installation is as shown in figure (When installing it on wall, height of hall should be about 40cm-130cm from floor).(As shown
in Fig.15)
●Wrong installation is shown in following figure (If the pipe is bent too much, it would easily cause malfunction.(As shown in Fig.16)
Fig.15
Fig.16
Fig.17
Fig.18
B. Disassemble heat discharge pipe
(1) Remove joint B
remove joint B from joint C.(As shown in Fig.17)
(2) Remove joint A: Press the clasp and lift joint A upwards to remove it.(As shown in Fig.18)
(3) Remove the window adapter. Pull out and remove the window adapter by pushing down two
“PUSH” markings, and slide and close the exhaust cover in the window panel. (Optional)
joint B+C
"PUSH"
"PUSH"
upwards
clasp
disassemble
joint A
●Put through the power supply and then press ON/OFF button on remote controller to start the unit.
●Press mode button to select auto, cooling, drying, fan or heating function, and then check if the unit operates normally.
●If ambient temperature is below 16°C, the unit cant operate in cooling mode.
8.6 Operation test