37
DC Inverter Multi
VRF Service Manual
DPOUSPM
7.1.3 Display View
PAGE
INDOOR UNIT
ERROR
AUTO
ROOM TEMP.
SWING SLEEP MELT
TIMER ON OFF
SET TEMP.
ERR CODE
COOL DRY FAN HEAT AUTO LOW
CHECK
MONITORING
DETECTING
TEST
MID HIGH
CENTER
ADDRESS
INITIALIZE
SINGLE SELECT
CTRL MODE
SYS
SET
IN-
DOOR
DO
MAIN
c
c
Mon. Tue. Wed.
Thu. Fri. Sat. Sun.
Year
MonD
ate
Hour
Min
1
3
2
4
5
6
10
12
11
13
14
9
15
16
8
7
Fig.7.1.3
1
Pagination/displays
present domain
Under select control mode, group no. that is present controlling is displayed;
Under addresses setting state, present Soft Add is displayed.
2
Present unit no.
Displays the soft address of communication module that the present checking or
controlling indoor unit is belonged as well as the address of indoor unit;
Format: Soft add—Indoor unit add
3
Error
Displays when there is error at any indoor or outdoor unit.
4
Operation mode
Displays every operation state mode of indoor unit
5
Speed display
Displays High, Medium, Low and Auto speed of indoor unit
6
Check
Under group control mode, it is displayed when checking grouping information;
Under address setting mode, it is displayed when checking hard address.
7
Error code
Displays when abnormal occur on operation state of present indoor unit.
8
Operation monitoring and
controlling /monitoring
When central control works in normal, operation monitoring displays; when control
signal is transmitted, operation monitoring and controlling is displayed.
9
System time
Displays present time, format is Y, M, D, H, M and week.
10
Timer setting
Timer On/Off on when Timer On/Off is set to present indoor unit
11
Pre-set temperature
Displays value of pre-set temperature
12
Swing and Defrost
Displays operation of swing at indoor unit and defrost at outdoor unit
13
Ambient temperature
Displays value of ambient temperature of present indoor unit
14
System setting
Setting operation mode of central control. It should be completed
by installation personnel, but not for users.
15
Control mode
Displays 3 control modes of Central, Single and Select controls
16
Displays of soft address
When Indoor on, addresses of present online indoor unit is displayed;
When domain on, soft address of present online communication module is displayed;
6SHFL¿FORFDWLRQRIFRQWUROOHGLQGRRUXQLWFDQRQO\EHDVFHUWDLQHG
:KHQVRIWDGGUHVV¿WV3URMHFW,QVWDOODWLRQ/LVW
Instruction to display interface:
System Setting: Including Address Setting and other functions, and it is set when installation personnel are
adjusting units. It is not recommended that users operate it. The usage of this function requires password.
$GGUHVV6HWWLQJ6LQFHFKDUDFWHUVIURPWRDUH¿[HGDVWKHDGGUHVVHVRIFRQWUROOLQJFRPPXQLFDWLRQ
modules displayed by central control (hereinafter called soft addresses), and the addresses of communication
modules themselves (hereinafter called hard addresses) are value from 0~254, thus there is address matching
problem between central control and controlled communication module. In order to solve this problem, address
mapping setting is required to be conducted before project adjusting!
Содержание GMV-PD100W/NAB-K
Страница 1: ...DCINVERTERMULTIVRF SERVICE MANUAL T1 R410A 50Hz GC201112 CENTRAL AIR CONDITIONERS...
Страница 5: ...1 DC Inverter Multi VRF Service Manual PRODUCT QSPEVDU...
Страница 11: ...7 DC Inverter Multi VRF Service Manual CONTROL DPOUSPM...
Страница 62: ...58 DC Inverter Multi VRF Service Manual INSTALLATION...
Страница 99: ...95 DC Inverter Multi VRF Service Manual MAINTENANCE...
Страница 118: ...114 DC Inverter Multi VRF Service Manual GMV Pd140W NaB M GMV Pd160W NaB M...
Страница 133: ...JF00300208...