Multi Variable Air Conditioners Ducted Type Indoor Unit

 

 

1 Safety Notices (Please be sure to abide ) 

 

Warning: If not abide strictly, it may cause severe damage to the unit or the people. 

 

Note: If not abide strictly, it may cause slight or medium damage to the unit or the 
people. 

 

This sign indicates that the operation must be prohibited. Improper operation may 
cause severe damage or death to people. 

 

This sign indicates that the items must be observed. Improper operation may cause 
damage to people or property. 

 

Please install the unit according 
to instructions in this manual. 
Read this manual carefully 
before starting up or checking 
the machine. 

 

Installation should be 
performed by dealer or 
qualified technicians. Do not 
install the product by 
yourself. Improper 
installation may result in 
water leakage, electric 
shock or fire hazard. 

 

Make sure the local power 
supply is in accordance with 
units before installation, and 
check the power supply 
carefully. 

 

This air conditioner must be 
properly grounded through 
the receptacle to avoid 
electric shock. The 
grounding 

wire shouldn’t be 

connected with gas pipe, 
water pipe, lightning arrester 
or telephone line. 

 

Please use specialized 
accessories or parts to carry 
out installation, or water 
leakage, electric shock, fire 
hazard may resulted. 

 

R410A refrigerant can 
produce poisonous gas once 
it meets fire, so please 
ventilate the room 
immediately if refrigerant 
leaks out during installation. 

 

Diameter of power cord must 
be large enough. Damaged 
power cord and connecting 
wire must be replaced by 
specialized electric cable. 

 

After the power cord is 
Connected, please install 
the cover of electric box to 
avoid danger. 

 

Nitrogen must be charged   
according to technical 
requirements. 

 

Short circuit is forbidden. Do 
not cancel the pressure 
switch in case the unit may 
be damaged. 

 

For units with wired controller, 
do not connect power supply 
until the wired controller is well 
installed. Otherwise, the wired 
controller cannot be used. 

 

When the installation is 
finished, please check and 
make sure the drain pipe, 
pipeline and electric wire are 
all well connected in order to 
avoid water leakage, 
refrigerant leakage, electric 
shock or fire hazard. 

 

Do not extend fingers or 
objects into air outlet or air 
return grille. 

 

If you use gas heater or 
petroleum heater in the 
same room, please open the 
door or window to maintain 
good air circulation in case 
the room may lack of 
oxygen. 

Содержание GMV ND50PHS/B-T

Страница 1: ...r Unit Models GMV ND22PHS B T GMV ND25PHS B T GMV ND28PHS B T GMV ND32PHS B T GMV ND36PHS B T GMV ND40PHS B T GMV ND45PHS B T GMV ND50PHS B T GMV ND56PHS B T GMV ND63PHS B T GMV ND71PHS B T GMV ND80PH...

Страница 2: ...operational test before leaving the factory In order to avoid damage due to improper disassembly and inspection which may impact the normal operation of unit please do not disassemble the unit by you...

Страница 3: ...m Testing 9 4 4 Installation of Air Duct 13 4 5 Installation of Wired Controller 15 5 Wiring Work 16 5 1Connection of Wire and Patch Board Terminal 16 5 2Power Cord Connection 17 5 3 Connection of Com...

Страница 4: ...pe water pipe lightning arrester or telephone line Please use specialized accessories or parts to carry out installation or water leakage electric shock fire hazard may resulted R410A refrigerant can...

Страница 5: ...set too low Keep the difference between indoor temp and outdoor temp within 5 C If abnormal condition occurs e g unpleasant smell please turn off the unit at once and disconnect power supply Then con...

Страница 6: ...Temp Rated Cooling 27 80 6 19 66 2 35 95 24 75 2 Rated Heating 20 68 0 15 59 0 7 44 6 6 42 8 3 Preparations for Installation Note Product graphics are only for reference Please refer to actual produc...

Страница 7: ...therwise by himself 3 2 Location for Installation 1 The appliance shall not be installed in the laundry 2 The top holder must be strong enough to support unit s weight 3 Drain pipe can drain water out...

Страница 8: ...the unit by yourself Please contact local dealer to arrange professional technicians for the installation Do not connect power until all installation work is finished 3 3 Requirements for Communicati...

Страница 9: ...nit and Indoor Outdoor Unit Wire size mm2 AWG Material Standard Remarks Light Ordinary polyvinyl chloride sheathed cord 60227 IEC 52 60227 IEC 53 L 1000m L 3280 5 6ft 2 0 75 2 AWG18 IEC 60227 5 1 If t...

Страница 10: ...ed person in order to avoid a hazard 2 Install cut off device near the unit The minimum distance between each stage of cut off device should be 3mm The same for both indoor unit and outdoor unit 4 Ins...

Страница 11: ...the indoor unit temporarily Assemble suspension bolt on the expansion bolt attach the hanger bracket to the suspension bolt Be sure to fix it securely by using a nut and washer from upper and lower s...

Страница 12: ...fig 4 2 2 Tighten the flaring nut with torque wrench Fig 4 2 3 Use pipe bend when bending the pipe and the bending angle should not be too small 4 Wrap the connection pipe and joint with sponge and th...

Страница 13: ...elines are used for several units the position of pipeline should be about 100mm lower than the drainage port of each unit In this case thicker pipes should be applied Fig 4 3 1 4 3 2 Drainage Pipe In...

Страница 14: ...l pipe in the same level please select the connection way as shown in following fig NO1 Connection of drainage pipe joints Fig4 3 7 NO2 Connection of downspout elbow Fig4 3 8 NO3 Inserting pipe connec...

Страница 15: ...1 In case of commissioning finished please energize the IDUs and switch to cooling or dry mode meanwhile the water pump operates you can check the draining through the transparent part of drain socke...

Страница 16: ...ade board with iron frame The junction of air duct should be well sealed in order to prevent air leakage The design and construction of air duct should comply with national requirements The edge of ai...

Страница 17: ...he back and the return air cover plate is at the bottom as shown in Fig 4 4 4 Fig 4 4 4 2 If the bottom return air is desired just change the place of the rectangular flange and the return air cover p...

Страница 18: ...ir baffle by sponge if the fresh air duct is not be used 2 Install the round flange so that the fresh air duct can be connected as Fig 4 4 7 3 Sealing and heat preservation should be done for both the...

Страница 19: ...The communication wires should be separated from power cord and connection wire between indoor unit and outdoor unit Adjust the static pressure via wired controller according to site circumstance 5 1C...

Страница 20: ...c box lid 2 Let the power cord pass through the wiring through holes 3 Connect the power cord to terminal L N 4 Fix the power card with wiring clamp 5 3 Connection of Communication Wire between Indoor...

Страница 21: ...ig 5 4 1 shows the installation of wired controller Fig 5 4 1 Fig 5 4 2 2 Fig 5 4 2 shows the installation of remote controller 3 Wired controller and receiving light board can be installed at the sam...

Страница 22: ...d by the same wired controller When the indoor unit is controlled by two wired controllers the addresses of the two wired controllers should be different through address setting Address 1 is for main...

Страница 23: ...lid table when cleaning the unit Do not clean the unit with hot water whose temperature is higher than 45 C to prevent fade or deformation Do not dry the filters by fire or it may catch fire or become...

Страница 24: ...air may cause electric shock or fire so please contact an authorized service center for professional service The following checks prior to contact may save your time and money Phenomenon Troubleshooti...

Страница 25: ......

Отзывы: