background image

 

 

To Users 

Thank you for selecting Gree product. Please read this instruction manual carefully 

before installing and using the product, so as to master and correctly use the product. In 
order to guide you to correctly install and use our product and achieve expected 
operating effect, we hereby instruct as below: 

(1)  This appliance can be used by children aged from 8 years and above and persons with 

reduced physical, sensory or mental capabilities or lack of experience and knowledge if they 
have been given supervision or instruction concerning use of the appliance in a safe way 
and understand the hazards involved. Children shall not play with the appliance. Cleaning 
and user maintenance shall not be made by children without supervision. 

(2)  In order to ensure reliability of product, the product may consume some power under 

stand-by status for maintaining normal communication of system and preheating refrigerant 
and lubricant. If the product is not to be used for long, cut off the power supply; please 
energize and preheat the unit in advance before reusing it.   

(3)  Please properly select the model according to actual using environment; otherwise it may 

impact the using convenience.   

(4)  This product can’t be installed at corrosive, inflammable or explosive environment or the 

place with special requirements, such as kitchen. Otherwise, it will affect the normal 
operation or shorten the service life of the unit, or even cause fire hazard or serious injury. 
As for above special places, please adopt special air conditioner with anti-corrosive or 
anti-explosion function.   

(5)  If the product needs to be installed, moved or maintained, please contact our designated 

dealer or local service center for professional support. Users should not disassemble or 
maintain the unit by themselves, otherwise it may cause relative damage, and our company 
will bear no responsibilities. 

(6)  All the illustrations and information in the instruction manual are only for reference. In order 

to make the product better, we will continuously conduct improvement and innovation. If 
there is adjustment in the product, please subject to actual product. 

 

Содержание GMV-ND100G/B4B-T

Страница 1: ...MV ND50G C2B T GMV ND36G B4B T GMV ND45G B6B T GMV ND56G C2B T GMV ND45G B4B T GMV ND50G B6B T GMV ND63G C2B T GMV ND50G B4B T GMV ND56G B6B T GMV ND71G C2B T GMV ND56G B4B T GMV ND63G B6B T GMV ND22G...

Страница 2: ...used for long cut off the power supply please energize and preheat the unit in advance before reusing it 3 Please properly select the model according to actual using environment otherwise it may impac...

Страница 3: ...turer 3 After verification the defect of product is directly caused by corrosive gas 4 After verification defects are due to improper operation during transportation of product 5 Operate repair mainta...

Страница 4: ...nect Cables and Terminals of Wiring Board 11 5 2 Power Cord Connection 12 5 3 Connection of Communication Line of IDU and ODU 12 5 4 Connection of Communication Line of Wired Controller 13 5 5 Illumin...

Страница 5: ...interface shall comply with electrical security requirement voltage shall be 220 240V 50Hz or 208 230V 60Hz current shall be referred to the table of Wiring Requirements in Section 3 4 and safety cla...

Страница 6: ...special accessories and parts for installation to prevent water leakage electric shock and fire hazard etc If refrigerant leakage happens please ventilate the room immediately Diameter of power cord...

Страница 7: ...onditioner can be cleaned only when it has been turned off and the power has been cut off otherwise it may cause electric shock or injury Never spray or flush water towards the air conditioner otherwi...

Страница 8: ...pointed service center for help Any personal injury or property loss caused by improper installation improper debug unnecessary repair or not following the instructions of this manual should not be th...

Страница 9: ...Please contact the local Gree appointed service center before installation Any malfunctioncaused by the unit that is not installed by the Gree appointed service center would probably not be dealt wit...

Страница 10: ...it 3 3 1 Select communication line for indoor unit and wired controller Fig 3 2 Material type Total length of communication line between indoor unit and wired controller L m feet Wire size mm2 AWG Mat...

Страница 11: ...D28G B4B T GMV ND36G B4B T GMV ND45G B4B T GMV ND50G B4B T GMV ND56G B4B T GMV ND63G B4B T GMV ND71G B4B T GMV ND80G B4B T GMV ND90G B4B T GMV ND100G B4B T 220 240V 50Hz 208 230V 60Hz 6 1 1 GMV ND22G...

Страница 12: ...22G B6B T GMV ND28G B6B T GMV ND36G B6B T GMV ND15G B4B T GMV ND18G B4B T GMV ND22G B4B T GMV ND28G B4B T GMV ND36G B4B T GMV ND22G C4B T GMV ND28G C4B T GMV ND36G C4B T GMV ND22G C2B T GMV ND28G C2B...

Страница 13: ...r side The center of the hole should be determined referring to Fig 4 2 2 Insert the piping hole sleeve into the hole to prevent the connected piping and wiring from being damaged when passing through...

Страница 14: ...ction pipe with two leading pipes and then tighten the joint nuts tightly Connect the connect pipe with the two relative leading pipe tie the nut on tie in of the connect pipe tightly NOTES Be careful...

Страница 15: ...unication wires should be separated from power cord and connection wire between indoor unit and outdoor unit Adjust the static pressure via wired controller according to site circumstance 5 1 Connect...

Страница 16: ...gent or similarly qualified persons in order to avoid a hazard That the appliance shall be installed in accordance with national wiring regulations This appliance incorporates an earth connection for...

Страница 17: ...be connected in parallel between terminal screw D1 and D2 as shown in Fig 5 5 5 4 Connection of Communication Line of Wired Controller 1 Open the cover of electric box of indoor unit 2 Lead the commun...

Страница 18: ...f the unit Shown in Fig 5 6 1 Cut down tailings 1 when only the power cord is led 2 Cut down tailings 1 2 or 1 2 3 when the connection cord and wire are led 3 The piping types are recommended 2 Let th...

Страница 19: ...e operating status of the indoor unit the power will be turned on and when there is no condensed water the power will be turned off Main board terminal CN35 It s used to detect the water overflow erro...

Страница 20: ...Multi Variable Air Conditioners Wall Mounted Type Indoor Unit 16 Fig 5 7 6 The Best Usage Method Fig 6 1 1 Adjust to proper indoor temperature too cool of indoor temperature is not good for health...

Страница 21: ...indoor and outdoor temperatures within 5 C 4 The better effect will be maintained by adjusting the guide louver downward for heating and horizontal for cooling 5 When the air conditioner is running do...

Страница 22: ...Clean the panel Clean it with a soft hair brush water and neutral cleaning fluid and then dry it CAUTION Do not use water above 45 C to wash the panel to prevent decoloration or deformation Install th...

Страница 23: ...ason 1 Clean filter and body of air conditioner 2 Cut off the main power supply of air conditioner 8 Table of Error Codes for Indoor Unit Error Code Content Error Code Content Error Code Content L0 In...

Страница 24: ...ER had been set on the wireless remote controller The cooling heating effect of the air conditioner was not good Is the temperature set properly Is the inlet outlet vent of the outdoor unit blocked Is...

Страница 25: ...te controller can make the guide louver swing up and down or makes the guide louver stop at a certain angle to have air supplied 2 Press the SWING button on the wireless remote controller to make the...

Страница 26: ......