Multi Variable Air Conditioners One-way Cassette Type Indoor Unit 

1 Safety Precautions   

 

(1)  This product can’t be installed at corrosive, inflammable or explosive environment or the 

place with special requirements, such as kitchen. Otherwise, it will affect the normal 
operation or shorten the service life of the unit, or even cause fire hazard or serious injury. As 
for the above special places, please adopt special air conditioner with anti-corrosive or 
anti-explosion function. 

(2)  Follow this manual to complete the installation work. Please read this manual carefully 

before turning on or repairing the unit. 

(3)  Installation should be conducted by the dealer or qualified personnel. Please do not attempt 

to install the air conditioner by yourself. Improper installation may lead to water leakage, 
electric shock or fire hazard, etc. 

(4)  Before installation, please check whether the power supply is complied with that specified on 

the nameplate and check the safety of the power supply.   

(5)  The air conditioner must be grounded reliably for avoiding electric shock. Please do not 

connect the earthing wire to gas pipe, water pipe, lightning rod or telephone line. 

(6)  Be sure to use special accessories and parts for installation to prevent water leakage, 

electric shock and fire hazard, etc. 

(7)  If refrigerant leakage happens, please ventilate the room immediately.   

(8)  Diameter of power cord should be large enough. The damaged power cord and connection 

wire must be replaced with special cables. 

(9)  When the power cord is connected, please fix the electric box cover properly to avoid safety 

accidents. 

(10) Never fail to comply with the nitrogen-charging welding process. Do charge nitrogen when 

welding the pipes.     

(11) Never short circuit or cancel the pressure switch to prevent unit damage.   

(12) As for the unit controlled by the wired controller, connect the wired controller well firstly and 

then energize the unit; otherwise, the unit can’t operate normally. 

(13) When installation is finished, please check whether the drainage pipes, pipelines and electric 

wires are connected correctly to avoid water leakage, refrigerant leakage, electric shock or 
fire, etc. 

(14) Do not insert fingers or objects into air outlet or air return grille. 

(15) Open the door and window frequently to keep good ventilation for avoiding oxygen deficit 

when gas heater or oil heater is used in the room. 

(16) Never plug in or unplug the power plug directly to turn on or turn off the air conditioner.   

(17) Once the air conditioner is turned on, it can be turned off only after it has operated for 5min 

at least; otherwise, it will affect the oil return of compressor. 

(18) Do not allow children to operate this air conditioner. 

(19) Do not operate this air conditioner with wet hands. 

(20) The air conditioner can be cleaned only when it has been turned off and the power has been 

cut off; otherwise, it may cause electric shock or injury. 

(21) Never spray or flush water towards the air conditioner; otherwise, malfunction or electric 

shock may happen. 

(22) Do not expose the air conditioner to the moist or corrosive environment. 

(23) Put through the power 8 hours in advance before operation. Do not cut off the power when 

the air conditioner stops operation for only about one night (protect the compressor).   

(24) Volatile liquid, such as diluent or gasoline, will damage the appearance of air conditioner. 

Only soft dry cloth and wet cloth dipped with neutral detergent can be used to clean the outer 
case of air conditioner. 

Содержание GMV-ND07TD/A-T

Страница 1: ...Owner s Manual Original Instructions Commercial Air Conditioners Multi Variable Air Conditioners One way Cassette Type Indoor Unit Models GMV ND07TD A T U GMV ND09TD A T U GMV ND12TD A T U...

Страница 2: ...ld well keep this manual 6 If this unit fails to operate normally please contact our service center as soon as possible and provide the following information 1 Content on the nameplate model number co...

Страница 3: ...turer 3 After verification the defect of product is directly caused by corrosive gas 4 After verification defects are due to improper operation during transportation of product 5 Operate repair mainta...

Страница 4: ...Drainage System Testing 9 4 4 Panel Installation 12 4 5 Installation of Wired Controller 13 5 Wiring Work 14 5 1 Connection of Wire and Patch Board Terminal 14 5 2 Power Cord Connection 15 5 3 Connec...

Страница 5: ...en charging welding process Do charge nitrogen when welding the pipes 11 Never short circuit or cancel the pressure switch to prevent unit damage 12 As for the unit controlled by the wired controller...

Страница 6: ...er for help Any personal injury or property loss caused by improper installation improper debug unnecessary repair or not following the instructions of this manual should not be the responsibility of...

Страница 7: ...e remote controller 14 Tapping screw 2 Used for fixing the remote controller holder 3 2 Installation Position Selection 1 The appliance shall not be installed in the laundry 2 The location should be a...

Страница 8: ...gulations 2 Only qualified personnel can carry out installation work please contact with local dealer before installation 3 Make sure all the installation work completed before energizing 3 3 Requirem...

Страница 9: ...eld or strong interference it is necessary to use shielded wire 3 3 2 Selection of Communication Wire between Indoor Unit and Indoor Unit or Outdoor Unit Fig 3 3 2 Material Type Total Length L m ft of...

Страница 10: ...ove sheet is based on ambient temperature of 40 104 4 The circuit breaker specification in above sheet is based on ambient temperature of 40 104 If the working condition is different please adjust it...

Страница 11: ...er and lower sides of the hanger bracket The washer fixing plate will prevent the washer from falling 3 The usage of paper pattern Refer to paper pattern of installation for ceiling opening dimension...

Страница 12: ...nd then tighten the flaring nut with hand as shown in Fig 4 2 1 2 Tighten the flaring nut with torque wrench Fig 4 2 1 Pipe diameter mm inch Torque N m 6 35 1 4 15 30 9 52 3 8 35 40 12 7 1 2 45 50 15...

Страница 13: ...to the drainage pipe Improper installation may lead to water leakage and damp the furniture and other things in the room 7 You can buy normal hard PVC pipe used as the drainage pipe During connection...

Страница 14: ...ation height of raising pipe for drainage should be lower than B The gradient from raising pipe towards drainage direction should be at least 1 2 If the raising pipe is vetical with the unit the raisi...

Страница 15: ...e g water pump etc 2 In case of commissioning finished please energize the IDUs and switch to cooling or dry mode meanwhile the water pump operates you can check the draining through the drain socket...

Страница 16: ...roper decorative panel installation could cause the following problems Fig 4 4 1 2 Ensure that its clearance free between decoration panel and ceiling board after installation if not please adjust the...

Страница 17: ...les and then install the corresponding screw cover 4 Close the horizon lover connect the butt terminal and arrange the wires 5 After tightening screws reinstall the air inlet grille Fig 4 4 4 4 5 Inst...

Страница 18: ...e communication wires should be separated from power cord and connection wire between indoor unit 8 Adjust the static pressure via wired controller according to site circumstance 5 1 Connection of Wir...

Страница 19: ...it can t operate normally Fig 5 2 1 1 Detach the electric box lid 2 Let the power cord pass through the wiring through holes 3 Connect wires according to Fig 5 2 1 4 Fix the power cord with wiring cla...

Страница 20: ...1 Open electric box cover of indoor unit 2 Let the communication wire go through the rubber ring 3 Connect the communication wire to terminal H1 and H2 of indoor 4 bit wiring board 4 Fix the communica...

Страница 21: ...s that must be set as master one and slave one 4 One wired controller can control 16 indoor unitS in maximum at the same time as shown in Fig 5 5 1 1 The type of indoor units must be the same if they...

Страница 22: ...Multi Variable Air Conditioners One way Cassette Type Indoor Unit 18 Fig 5 5 1...

Страница 23: ...outlet of indoor and outdoor unit are blocked 2 Check if securely grounded 3 Check if all the power cord and communication cable are securely connected 4 Check if any error code displayed after energ...

Страница 24: ...y leakage of electricity Input voltage is too low Defect of main PC board The unit stops after running for a while The inlet or outlet of ODU or IDU are blocked by obstacle Poor cooling effect The fil...